全髋置换患者1.5T与3T前列腺MRI伪影严重程度比较与预测
回顾性多中心队列研究纳入140例单侧或双侧全髋置换患者,比较1.5T与3T多参数前列腺MRI的伪影严重程度和诊断价值。结果显示两场强在DWI和定位像伪影及整体诊断价值上无显著差异,定位像伪影与诊断价值强相关,最新一代3T扫描仪DWI图像质量显著改善。
要点
- 全髋置换患者1.5T与3T前列腺mpMRI伪影严重程度无显著差异,两场强均可用于检查。
- 定位像伪影严重程度与整体诊断价值强相关,可作为早期预测诊断价值和决定是否增强的参考。
- 最新一代3T扫描仪DWI图像质量显著改善,建议优先使用先进设备及rs/ptx-EPI DWI序列。
关键影像表现/征象
- T2w和DCE序列整体伪影较低。
- DWI和定位像的伪影严重程度在1.5T与3T间无显著差异。
- 整体诊断价值与定位像及DWI的伪影严重程度、PI-QUAL评分强相关。
- 最新一代3T扫描仪的图像质量显著改善,尤其DWI(p < 0.03)。
诊断标准与关键数值
- 伪影严重程度采用3分制评分,评估定位像及mpMRI序列(T2w、DWI、DCE)。
- 图像质量采用PI-QUAL评分评估。
- 诊断价值与伪影严重程度及PI-QUAL评分强相关。
临床应用与阅片要点
- 全髋置换患者行前列腺mpMRI时不必因场强选择而延迟检查,1.5T和3T均可接受。
- 阅片时重点关注定位像伪影,其严重程度可提示整体诊断价值并辅助决定是否使用对比剂。
- DWI伪影与诊断价值强相关,应优先选用rs/ptx-EPI DWI序列及最新一代3T设备以改善图像质量。
- T2w和DCE序列伪影通常较轻,可作为可靠的结构和动态增强评估序列。
局限性
- 回顾性研究设计。
- 原文未报告其他明显局限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate image quality and diagnostic value of multiparametric prostate MRI (mpMRI) in patients with total hip replacement (THR) at 1.5 and 3 Tesla.
METHODS: In this retrospective multicenter cohort study patients with uni- or bilateral THR and 1.5 T or 3 T mpMRI were included. Seventy consecutive, standard-of-care examinations per field strength were evaluated regarding their diagnostic value. The overall diagnostic value and prostate imaging quality score (PI-QUAL) were assessed. Artifact severity in the localizer and mpMRI sequences (T2w, DWI, DCE) was scored on a 3-point scale. Correlation between diagnostic value and artifacts was analysed. Moreover, a subgroup analysis focussed on image quality at different 3 T scanner generations.
RESULTS: 140 consecutive patients (mean age 72, median PSA value 8.3 ng/ml) were included. When comparing 1.5 T to 3 T examinations, no significant differences were observed regarding the artifact severity of DWI and the localizer and the overall diagnostic value of the images. There was a strong correlation between the diagnostic value, PI-QUAL score, and artifact severity in the localizer and DWI. T2w and DCE sequences showed overall low artifacts. Significant improvement in image quality for 3 T at the latest scanner generation was observed, especially for DWI (p < 0.03).
CONCLUSIONS: MpMRI of patients with THR can be conducted at both field strengths without significant differences in artifacts. The localizer might be useful as an early forecasting feature for diagnostic value and particularly for contrast medium application decision. Patients with THR could benefit from technically advanced scanner generation and rs/ptx-EPI DWI sequences.
引用
- Boschheidgen M, Ullrich T, Blondin D, et al. Comparison and prediction of artefact severity due to total hip replacement in 1.5 T versus 3 T MRI of the prostate. Eur J Radiol. 2021. PMID: 34537450. doi:10.1016/j.ejrad.2021.109949
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。