文献速递泌尿生殖腹部MR

机器学习ADC与T2W影像组学特征预测PI-RADS 3病变前列腺癌诊断

Utility of machine learning of apparent diffusion coefficient (ADC) and T2-weighted (T2W) radiomic features in PI-RADS version 2.1 category 3 lesions to predict prostate cancer diagnosis.
PubMed 文献 · Abdom Radiol (NY) · 2021-08-31

多中心回顾性病例对照研究评估158例男性160个PI-RADS v2.1 3类病变,使用机器学习分析ADC和T2W影像组学特征预测前列腺癌诊断。结果显示ADC影像组学对临床显著前列腺癌的AUC为0.684,对任何前列腺癌的AUC为0.642,T2W的AUC分别为0.547和0.608,提示至多中等准确度。

要点

  • ADC影像组学对临床显著前列腺癌的AUC为0.684,优于T2W的0.547。
  • T2W影像组学对任何前列腺癌的AUC为0.608,ADC为0.642。
  • 机器学习模型对PI-RADS 3病变的预测准确度至多为中等,尚不足以替代活检。
英文原文(摘要)· 点击展开

PURPOSE: To evaluate if machine learning (ML) of radiomic features extracted from apparent diffusion coefficient (ADC) and T2-weighted (T2W) MRI can predict prostate cancer (PCa) diagnosis in Prostate Imaging-Reporting and Data System (PI-RADS) version 2.1 category 3 lesions.

METHODS: This multi-institutional review board-approved retrospective case-control study evaluated 158 men with 160 PI-RADS category 3 lesions (79 peripheral zone, 81 transition zone) diagnosed at 3-Tesla MRI with histopathology diagnosis by MRI-TRUS-guided targeted biopsy. A blinded radiologist confirmed PI-RADS v2.1 score and segmented lesions on axial T2W and ADC images using 3D Slicer, extracting radiomic features with an open-source software (Pyradiomics). Diagnostic accuracy for (1) any PCa and (2) clinically significant (CS; International Society of Urogenital Pathology Grade Group ≥ 2) PCa was assessed using XGBoost with tenfold cross -validation.

RESULTS: From 160 PI-RADS 3 lesions, there were 50.0% (80/160) PCa, including 36.3% (29/80) CS-PCa (63.8% [51/80] ISUP 1, 23.8% [19/80] ISUP 2, 8.8% [7/80] ISUP 3, 3.8% [3/80] ISUP 4). The remaining 50.0% (80/160) lesions were benign. ML of all radiomic features from T2W and ADC achieved area under receiver operating characteristic curve (AUC) for diagnosis of (1) CS-PCa 0.547 (95% Confidence Intervals 0.510-0.584) for T2W and 0.684 (CI 0.652-0.715) for ADC and (2) any PCa 0.608 (CI 0.579-0.636) for T2W and 0.642 (CI 0.614-0.0.670) for ADC.

CONCLUSION: Our results indicate ML of radiomic features extracted from T2W and ADC achieved at best moderate accuracy for determining which PI-RADS category 3 lesions represent PCa.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Lim CS, Abreu-Gomez J, Thornhill R, et al. Utility of machine learning of apparent diffusion coefficient (ADC) and T2-weighted (T2W) radiomic features in PI-RADS version 2.1 category 3 lesions to predict prostate cancer diagnosis. Abdom Radiol (NY). 2021. PMID: 34467426. doi:10.1007/s00261-021-03235-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。