超高b值(3000 s/mm²)扩散加权MRI在前列腺癌3T中的临床影响:与b值2000 s/mm²的比较
本研究纳入49例前列腺癌患者,在3T多参数MRI上比较b值3000 s/mm²的超高b值DWI与b值2000 s/mm²的高b值DWI。结果显示超高b值DWI能更好地抑制背景信号,但在病灶清晰度、信噪比、对比噪声比及鉴别Gleason分级≤2与≥3的AUC上均无显著优势。
要点
- 超高b值DWI(3000 s/mm²)较b值2000 s/mm²能更显著抑制良性前列腺背景信号。
- 两者在解剖变形、病灶清晰度评分、信噪比及对比噪声比上无显著差异。
- 超高b值DWI未提高区分Gleason分级≤2与≥3的AUC(0.699 vs 0.731,P=0.161)。
关键影像表现/征象
- 超高b值DWI上良性前列腺信号强度显著低于高b值DWI(p<0.001)。
- 两种b值DWI上病灶ADC均显著低于周围良性组织ADC(均p<0.001)。
- 超高b值DWI与高b值DWI在解剖变形、病灶清晰度评分、信噪比及对比噪声比上均无显著差异(均p>0.05)。
诊断标准与关键数值
- 区分Gleason分级≤2与≥3的AUC:高b值DWI为0.731,超高b值DWI为0.699,两者比较p=0.161。
- 病灶ADC在≤GG2与≥GG3肿瘤间差异:高b值DWI p=0.021,超高b值DWI p=0.007。
临床应用与阅片要点
- 超高b值DWI可用于抑制前列腺背景信号,但不应期望其提高肿瘤检出或分级判别能力。
- 阅片时需注意两种b值DWI的图像质量与病灶清晰度相当,选择b值3000并非必需。
局限性
- 单中心小样本(49例)回顾性研究。
- 未报告观察者间一致性及病理参考标准的详细细节。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: High b-value diffusion-weighted imaging (hDWI) with a b-value of 2000 s/mm2 provides insufficient image contrast between benign and malignant tissues and an overlap of apparent diffusion coefficient (ADC) between Gleason grades (GG) in prostate cancer (PC). We compared image quality, PC detectability, and discrimination ability for PC aggressiveness between ultra-high b-value DWI (uhDWI) of 3000 s/mm2 and hDWI.
METHODS: The subjects were 49 patients with PC who underwent 3T multiparametric MRI. Single-shot echo-planar DWI was acquired with b-values of 0, 2000, and 3000 s/mm2. Anatomical distortion of prostate (AD), signal intensity of benign prostate (PSI), and lesion conspicuity score (LCS) were assessed using a 4-point scale; and signal-to-noise ratio, contrast-to-noise ratio, and mean ADC (×10-3 mm2/s) of lesion (lADC) and surrounding benign region (bADC) were measured.
RESULTS: PSI was significantly lower in uhDWI than in hDWI (p < 0.001). AD, LCS, signal-to-noise ratio, and contrast-to-noise ratio were comparable between uhDWI and hDWI (all p > 0.05). In contrast, lADC was significantly lower than bADC in both uhDWI and hDWI (both p < 0.001). In comparison of lADC between tumors of ≤GG2 and those of ≥GG3, both uhDWI and hDWI showed significant difference (p = 0.007 and p = 0.021, respectively). AUC for separating tumors of ≤GG2 from those of ≥GG3 was 0.731 in hDWI and 0.699 in uhDWI (p = 0.161).
CONCLUSION: uhDWI suppressed background signal better than hDWI, but did not contribute to increased diagnostic performance in PC.
ADVANCES IN KNOWLEDGE: Compared with hDWI, uhDWI could not contribute to increased diagnostic performance in PC.
引用
- Tamada T, Kido A, Ueda Y, et al. Clinical impact of ultra-high b-value (3000 s/mm2) diffusion-weighted magnetic resonance imaging in prostate cancer at 3T: comparison with b-value of 2000 s/mm2. Br J Radiol. 2021. PMID: 34558293. doi:10.1259/bjr.20210465
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。