文献速递泌尿生殖腹部MR

分剂量钆特酸葡胺动态增强MRI检测前列腺癌的有效性

Effectiveness of Dynamic Contrast Enhanced MRI with a Split Dose of Gadoterate Meglumine for Detection of Prostate Cancer.
PubMed 文献 · Acad Radiol · 2021-09-25

结果显示分剂量方案获得的动脉输入函数(AIF)峰值更高,且用30%剂量数据的AIF分析70%剂量数据可提高Ktrans在外周带和中央带的诊断效能。

要点

  • 分剂量注射方案(30%+70%)可清晰显示AIF的第一和第二通过,且峰值幅度更高。
  • 前列腺癌组织的Ktrans在外周带和中央带显著高于正常组织,但在移行带存在重叠。
  • 使用30%剂量数据的AIF分析70%剂量数据可提升Ktrans在外周带和中央带的诊断效能。

关键影像表现/征象

  • 30%剂量数据获得的AIF清晰显示第一和第二通过,且峰值幅度远高于70%剂量数据的AIF。
  • 在前列腺外周带和中央带,癌组织的Ktrans在70%剂量数据及用缩放AIF分析的70%剂量数据中均显著大于正常组织(p < 0.05)。
  • 移行带癌组织的Ktrans与正常组织存在重叠。
  • 癌组织与正常组织的ve无统计学差异。

诊断标准与关键数值

  • 使用30%剂量数据的AIF分析70%剂量数据,可提高Ktrans在外周带和中央带的诊断效能(ROC分析)。

临床应用与阅片要点

  • 在行前列腺DCE-MRI时,可考虑采用分剂量注射方案以改善AIF质量,从而提高定量参数Ktrans的诊断价值。
  • 判读Ktrans时需注意移行带癌与正常组织存在重叠,避免假阳性。

局限性

  • 未报告敏感度、特异度、AUC等具体诊断效能数值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate whether dynamic contrast enhanced (DCE) MRI with a split injection of 30% followed by 70% of a standard dose (30PSD and 70PSD) of gadoterate meglumine (DOTAREM) can improve diagnosis of prostate cancer (PCa).

MATERIALS AND METHODS: MRI for twenty patients was performed on a Philips Ingenia 3T scanner without an endorectal coil followed by subsequent radical prostatectomy. DCE 3D T1-FFE data were acquired with injection of 0.03 mmol/kg followed after 2 minutes by 0.07 mmol/kg of DOTAREM. Regions-of-interest on histologically verified PCa and normal tissue in different prostate zones and the iliac artery were drawn. Average signal intensity as function of time was calculated for each ROI and fitted by using the signal intensity form of the Tofts (SI-Tofts) model to extract physiological parameters (Ktrans and ve). In addition, the scaled arterial input function (AIF) obtained from 30PSD data was used to analyze 70PSD data.

RESULTS: The AIF obtained from 30PSD data showed both first and second passes clearly and had much higher peak magnitude than AIFs from 70PSD data. Ktrans was significantly (p < 0.05) larger in PCa than in normal tissue in peripheral zone (PZ) and central zone (CZ) for both 70PSD and 70PSD data analyzed with a scaled AIF. Ktrans in cancer overlapped with that of normal tissue in the transition zone (TZ). There was no statistical difference in ve between cancer and normal tissue. Receiver operating characteristic analysis showed that use of the AIF from 30PSD data to analyze 70PSD data increased the diagnostic efficacy of Ktrans in the PZ and CZ.

CONCLUSION: The split dose protocol for injection of Dotarem increased diagnostic accuracy of quantitative analysis with the SI-Tofts model.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Fan X, Chatterjee A, Pittman JM, et al. Effectiveness of Dynamic Contrast Enhanced MRI with a Split Dose of Gadoterate Meglumine for Detection of Prostate Cancer. Acad Radiol. 2021. PMID: 34583866. doi:10.1016/j.acra.2021.07.028

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。