文献速递泌尿生殖外周血管US

标准化结构化报告超声筛查移植肾动脉狭窄风险分层的验证研究

Ultrasound Screening for Transplant Renal Artery Stenosis Risk Stratification Using Standardized Criteria in Structured Reporting: A Validation Study.
PubMed 文献 · J Ultrasound Med · 2021-09-18

该研究纳入530例移植肾超声结构化报告,按三项标准(肾动脉流速≥300 cm/s、频谱增宽、实质内加速时间≥0.1秒)进行TRAS风险分层。结果显示风险分层与后续血管造影实施率及造影阳性率均显著相关(P < .01),低风险组无造影阳性,极高风险组造影阳性率达95%。结论认为该标准化筛查工具有效筛选需血管造影的患者。

要点

  • TRAS风险分层基于三项超声标准:肾动脉流速≥300 cm/s、频谱增宽、实质内加速时间≥0.1秒。
  • 风险分层与造影实施率和TRAS阳性率显著相关,低风险组无需造影。
  • 极高风险组(3/3标准)造影阳性率95%,应积极建议造影。

关键影像表现/征象

  • TRAS风险分层基于肾动脉流速≥300 cm/s、肾动脉频谱增宽、实质内加速时间≥0.1秒三项标准。
  • 低风险组(0/3)370例中仅7例(2%)行造影,无TRAS阳性。
  • 极高风险组(3/3)27例中20例(74%)行造影,19例(95%)阳性。

诊断标准与关键数值

  • TRAS风险分层标准:肾动脉流速≥300 cm/s、肾动脉频谱增宽、实质内加速时间≥0.1秒。
  • 风险分级:低风险(0/3)、中风险(1/3)、高风险(2/3)、极高风险(3/3)。
  • 各风险组造影阳性率:低风险0%(0/7)、中风险33%(8/24)、高风险61%(14/23)、极高风险95%(19/20)。

临床应用与阅片要点

  • 日常阅片应按标准测量肾动脉流速、观察频谱增宽、测量实质内加速时间并记录风险分级。
  • 低风险组可避免不必要的血管造影,极高风险组应建议造影。
  • 结构化报告有助于标准化描述和临床决策。

局限性

  • 单中心回顾性设计,样本来自单一机构。
  • 仅纳入临床考虑TRAS的超声检查,存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the effectiveness of templated ultrasound reports using transplant renal artery stenosis (TRAS) risk stratification (RS), particularly with regard to utilization of downstream angiographic studies and angiographic presence of TRAS.

METHODS: Ultrasounds with TRAS-RS templated reports from August 2017 to May 2020 were included. Studies were excluded if performed <28 days posttransplant and where TRAS was not clinically considered. A total of 530 ultrasounds met inclusion/exclusion criteria. TRAS-RS criteria were recorded (renal artery velocity ≥300 cm/s, spectral broadening in the renal artery, and intraparenchymal acceleration time ≥0.1 second). Depending on the number of criteria present, recipients were stratified into low (0/3), intermediate (1/3), high (2/3), and very high (3/3) risk for TRAS. Student's t-test was performed to identify whether the TRAS-RS category was associated with 1) performance of angiography to assess for TRAS and 2) angiographic presence of TRAS.

RESULTS: Of the 530 ultrasounds, 74 (14%) underwent angiography. Of these, 41 (55%) were positive for TRAS (overall positive rate, 8%). Number of ultrasounds, angiograms, and angiograms positive for TRAS, respectively, in each of the TRAS-RS categories for the 530 cases were: low probability: n = 370 (70% of all studied reports), 7 angiograms (2%), and 0 (0%) positive for TRAS; intermediate: n = 87 (16%), 24 angiograms (28%), and 8 (33%) positive; high: n = 46 (9%), 23 angiograms (50%), and 14 (61%) positive; and very high: n = 27 (5%), 20 angiograms (74%), and 19 (95%) positive. TRAS-RS score was associated with subsequent performance of angiography and positive rate for TRAS (P < .01).

CONCLUSION: Implementing a defined ultrasound screening tool with templated reporting for TRAS allowed for effective selection of those requiring an angiogram.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Fananapazir G, LaRoy JR, Navarro SM, et al. Ultrasound Screening for Transplant Renal Artery Stenosis Risk Stratification Using Standardized Criteria in Structured Reporting: A Validation Study. J Ultrasound Med. 2021. PMID: 34536039. doi:10.1002/jum.15826

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。