文献速递泌尿生殖MR

非平行传输缩放DWI较常规DWI改善病灶显示并提高前列腺癌检出

Better lesion conspicuity translates into improved prostate cancer detection: comparison of non-parallel-transmission-zoomed-DWI with conventional-DWI.
PubMed 文献 · Abdom Radiol (NY) · 2021-09-12

该回顾性研究纳入98例接受常规DWI、非平行传输缩放DWI及T2WI的前列腺患者,比较两种DWI的图像质量及基于PI-RADS v2的癌灶检出效能。非平行传输缩放DWI图像质量与可重复性更优,以PI-RADS 4分为阈值时对总体前列腺癌和临床重要前列腺癌的敏感度、特异度均显著高于常规DWI。

要点

  • 非平行传输缩放DWI图像质量及分析可重复性均优于常规DWI。
  • 以PI-RADS 4分为阈值,缩放DWI对总体前列腺癌检出敏感度87.9%、特异度87.5%。
  • 缩放DWI对临床重要前列腺癌检出敏感度86.3%、特异度72.3%。

核心结论

  • 非平行传输缩放DWI的图像质量和前列腺癌检出效能均优于常规DWI。

研究设计与样本

  • 回顾性研究纳入98例患者,均行常规DWI、非平行传输缩放DWI及T2WI。
  • 以PI-RADS v2评分和ADC值比较两种DWI对总体前列腺癌和临床重要前列腺癌的检出能力。

关键影像表现/征象

  • 非平行传输缩放DWI的图像质量(包括前列腺畸变和伪影存在情况)显著优于常规DWI(P<0.001)。
  • 非平行传输缩放DWI的图像分析可重复性显著优于常规DWI(P<0.001)。

诊断标准与关键数值

  • 以PI-RADS 4分为预测前列腺癌的阈值,缩放DWI对总体前列腺癌的敏感度87.9%、特异度87.5%,常规DWI分别为72.4%、77.5%(均P<0.05)。
  • 以PI-RADS 4分为阈值,缩放DWI对临床重要前列腺癌的敏感度86.3%、特异度72.3%,常规DWI分别为74.5%、63.8%(均P≤0.001)。
  • 缩放DWI的ADC值对总体前列腺癌的AUC为0.827,常规ADC为0.797(P=0.55)。
  • 缩放DWI的ADC值对临床重要前列腺癌的AUC为0.822,常规ADC为0.749(P=0.58)。

临床应用与阅片要点

  • 采用非平行传输缩放DWI可改善前列腺病灶的显示和图像分析可重复性,有助于提高前列腺癌检出。
  • 以PI-RADS 4分为阈值时,缩放DWI对总体和临床重要前列腺癌的敏感度和特异度均更高。

局限性

  • 本研究为回顾性设计。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare advanced non-parallel transmission zoomed diffusion-weighted imaging (nonPTX zoom-DWI) to conventional DWI (conv-DWI) for the assessment of prostate cancer (PCa).

METHODS: This retrospective study included 98 patients who underwent conv-DWI, nonPTX zoom-DWI, and T2-weighted imaging of the prostate. The image qualities of the two DWI sets, including the distortion of the prostate and the existence of artifacts, were evaluated. To compare the overall PCa and clinically important PCa (ciPCa) detection ability between the sets, lesions were scored using the Prostate Imaging Reporting and Data System (PI-RADS) version 2. Apparent diffusion coefficient (ADC) values of the lesions were also measured and compared. The Mann-Whitney U test was used to compare continuous variables, and the χ2 test was used to compare categorical variables. Two-sided P values of < 0.05 were considered significant.

RESULTS: Non-PTX zoom-DWI yielded significantly better image quality and image analysis reproducibility than conv-DWI (all P < 0.001). Compared with conv-ADC, nonPTX zoom-ADC showed slightly better detection performance for overall PCa (AUC: 0.827 vs. 0.797; P = 0.55) and ciPCa (AUC: 0.822 vs. 0.749; P = 0.58). At a PI-RADS score of 4 as the cutoff value for PCa prediction, nonPTX zoom-DWI showed significantly higher diagnostic efficiency for overall PCa detection (sensitivity: 87.9% vs. 72.4%; specificity: 87.5% vs. 77.5%; both P < 0.05) and ciPCa detection (sensitivity: 86.3% vs. 74.5%; specificity: 72.3% vs. 63.8%; both P ≤ 0.001).

CONCLUSION: Non-PTX zoom-DWI yields better image quality and higher PCa detection performance than Conv-DWI.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Hu L, Wei L, Wang S, et al. Better lesion conspicuity translates into improved prostate cancer detection: comparison of non-parallel-transmission-zoomed-DWI with conventional-DWI. Abdom Radiol (NY). 2021. PMID: 34514538. doi:10.1007/s00261-021-03268-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。