文献速递技术与安全胸部腹部PETCT

数据驱动呼吸门控在肿瘤患者PET/CT中的临床评估:对图像质量和患者管理的影响

Clinical evaluation of data-driven respiratory gating for PET/CT in an oncological cohort of 149 patients: impact on image quality and patient management.
PubMed 文献 · Br J Radiol · 2021-09-14

该回顾性研究纳入149例肿瘤分期或再分期患者,比较启用与未启用数据驱动呼吸门控(DDG)重建的PET图像。DDG显著减少运动伪影、提升器官轮廓清晰度,并在27%患者中改变报告、8%患者中改变临床管理,但整体图像质量评分无差异,平均扫描时间增加4分37秒。

要点

  • DDG可减少呼吸运动伪影、提高器官轮廓清晰度,阅片时注意结合DDG图像评估病灶。
  • DDG在27%患者中导致报告改变,8%患者临床管理改变,提示其对决策有潜在影响。
  • DDG无需外部门控设备,但平均每例增加约4分37秒扫描时间,需权衡流程效率。

核心结论

  • 无外部设备的数据驱动呼吸门控可在临床常规中提供可靠的全自动运动校正,提高病灶可检测性并在相当数量患者中改变临床管理。

研究设计与样本

  • 单中心回顾性研究,纳入149例因癌症分期或再分期行PET/CT的患者,使用数字探测器扫描仪,每例重建DDG启用与未启用的PET数据集,由两名读者评估。

关键影像表现/征象

  • DDG图像中运动效应(整体模糊)评分显著低于非DDG图像,肝脏和脾脏等器官轮廓显著更清晰(均p < 0.001)。
  • DDG与非DDG图像的整体图像质量评分无显著差异(p = 1.000)。

诊断标准与关键数值

  • 在85%(n=126)患者中至少一个床位使用DDG采集,全研究队列(n=149)平均扫描时间增加4分37秒。
  • 27%患者中DDG导致报告改变,8%(12例)患者中DDG导致进一步临床管理改变。

临床应用与阅片要点

  • 日常阅片时应关注DDG重建图像,利用其减少的运动伪影和更清晰的器官轮廓来辅助病灶检出与报告。
  • 对于呼吸运动明显或病灶位于膈肌附近的患者,DDG可能额外提供诊断信息,但需注意扫描时间延长对流程的影响。

局限性

  • 回顾性单中心设计,样本量有限,未报告读者间一致性及具体病灶层面的检出率数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the impact of fully automatic motion correction by data-driven respiratory gating (DDG) on positron emission tomography (PET) image quality, lesion detection and patient management.

MATERIALS AND METHODS: A total of 149 patients undergoing PET/CT for cancer (re-)staging were retrospectively included. Patients underwent a PET/CT on a digital detector scanner and for every patient a PET data set where DDG was enabled (PETDDG) and as well as where DDG was not enabled (PETnonDDG) was reconstructed. All PET data sets were evaluated by two readers which rated the general image quality, motion effects and organ contours. Further, both readers reviewed all scans on a case-by-case basis and evaluated the impact of PETDDG on additional apparent lesion, change of report, and change of management.

RESULTS: In 85% (n = 126) of the patients, at least one bed position was acquired using DDG, resulting in mean scan time increase of 4:37 min per patient in the whole study cohort (n = 149). General image quality was not rated differently for PETnonDDG and PETDDG images (p = 1.000) while motion effects (i.e. indicating general blurring) was rated significantly lower in PETDDG images and organ contours, including liver and spleen, were rated significantly sharper using PETDDG as compared to PETnonDDG (all p < 0.001). In 27% of patients, PETDDG resulted in a change of the report and in a total of 12 cases (8%), PETDDG resulted in a change of further clinical management.

CONCLUSION: Deviceless DDG provided reliable fully automatic motion correction in clinical routine and increased lesion detectability and changed management in a considerable number of patients.

ADVANCES IN KNOWLEDGE: DDG enables PET/CT with respiratory gating to be used routinely in clinical practice without external gating equipment needed.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Messerli M, Liberini V, Grünig H, et al. Clinical evaluation of data-driven respiratory gating for PET/CT in an oncological cohort of 149 patients: impact on image quality and patient management. Br J Radiol. 2021. PMID: 34520673. doi:10.1259/bjr.20201350

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。