文献速递儿科影像腹部技术与安全CT

儿童CT患者水平剂量监测:管电流调制下多次多序列检查的累积剂量追踪

Patient-level dose monitoring in computed tomography: tracking cumulative dose from multiple multi-sequence exams with tube current modulation in children.
PubMed 文献 · Pediatr Radiol · 2021-09-17

该回顾性研究纳入48名儿童共143个腹盆部CT序列,提出患者尺寸特异的z轴剂量轮廓及剂量线积分(DLI)作为新剂量指标。结果显示累积轮廓峰值剂量较ΣSSDE高20.6%,ΣDLI较ΣDLP高114%,提示传统简单求和会低估累积剂量。

要点

  • 儿童多次CT累积剂量不宜简单相加CTDIvol或SSDE。
  • z轴剂量轮廓峰值剂量较ΣSSDE高20.6%,应关注峰值而非仅求和。
  • ΣDLI较ΣDLP高114%,DLI更能反映总体能量吸收。

局限性

  • 单中心回顾性研究,样本量有限。
  • 仅纳入腹盆部CT,未涉及其他部位。
  • 需手动识别肠系膜上动脉起源以对齐轮廓,操作依赖人工。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: In children exposed to multiple computed tomography (CT) exams, performed with varying z-axis coverage and often with tube current modulation, it is inaccurate to add volume CT dose index (CTDIvol) and size-specific dose estimate (SSDE) to obtain cumulative dose values.

OBJECTIVE: To introduce the patient-size-specific z-axis dose profile and its dose line integral (DLI) as new dose metrics, and to use them to compare cumulative dose calculations against conventional measures.

MATERIALS AND METHODS: In all children with 2 or more abdominal-pelvic CT scans performed from 2013 through 2019, we retrospectively recorded all series kV, z-axis tube current profile, CTDIvol, dose-length product (DLP) and calculated SSDE. We constructed dose profiles as a function of z-axis location for each series. One author identified the z-axis location of the superior mesenteric artery origin on each series obtained to align the dose profiles for construction of each patient's cumulative profile. We performed pair-wise comparisons between the peak dose of the cumulative patient dose profile and ΣSSDE, and between ΣDLI and ΣDLP.

RESULTS: We recorded dose data in 143 series obtained in 48 children, ages 0-2 years (n=15) and 8-16 years (n=33): ΣSSDE 12.7±6.7 and peak dose 15.1±8.1 mGy, ΣDLP 278±194 and ΣDLI 550±292 mGy·cm. Peak dose exceeded ΣSSDE by 20.6% (interquartile range [IQR]: 9.9-26.4%, P<0.001), and ΣDLI exceeded ΣDLP by 114% (IQR: 86.5-147.0%, P<0.001).

CONCLUSION: Our methodology represents a novel approach for evaluating radiation exposure in recurring pediatric abdominal CT examinations, both at the individual and population levels. Under a wide range of patient variables and acquisition conditions, graphic depiction of the cumulative z-axis dose profile across and beyond scan ranges, including the peak dose of the profile, provides a better tool for cumulative dose documentation than simple summations of SSDE. ΣDLI is advantageous in characterizing overall energy absorption over ΣDLP, which significantly underestimated this in all children.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Tabari A, Li X, Yang K, et al. Patient-level dose monitoring in computed tomography: tracking cumulative dose from multiple multi-sequence exams with tube current modulation in children. Pediatr Radiol. 2021. PMID: 34532817. doi:10.1007/s00247-021-05160-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。