腹部增强MDCT个体化与固定扫描延迟的患者内比较:图像质量评估
定量分析显示SP期腹主动脉和门静脉强化显著更高(p<0.001),定性分析显示SP期多数腹部脏器显示更清晰(p<0.001)。结论认为SP可能比PVP更适合非创伤性急腹症的CT评估。
要点
- SP扫描延迟67±8秒,较PVP的90秒更早,血管强化更高。
- SP期腹主动脉和门静脉CT值显著高于PVP期(p<0.001)。
- SP期多数腹部脏器定性显示更清晰,观察者间一致性k为0.60-0.88。
核心结论
- 单期方案(SP)较门静脉期(PVP)产生显著更高的血管强化和更清晰的多数腹部脏器显示,可能更适合非创伤性急腹症的CT评估。
研究设计与样本
- 对比剂为非离子型碘对比剂(370 mgI/ml),剂量1.7 cc/Kg,注射速率2.0 cc/sec;SP扫描延迟67±8秒,PVP延迟90秒。
关键影像表现/征象
- SP期腹主动脉CT值232±53 HU,显著高于PVP期的180±36 HU(p<0.001)。
- SP期门静脉CT值215±39 HU,显著高于PVP期的187±42 HU(p<0.001)。
- 定性分析显示SP期多数腹部脏器显示更清晰(p<0.001)。
诊断标准与关键数值
- 计算了多数内脏器官及腹主动脉和门静脉的信噪比(SNR)和对比噪声比(CNR)。
- 定性分析采用盲法评估腹部脏器和血管结构的显示,观察者间一致性用加权Cohen kappa分析,除一项标准外k值为0.60-0.88。
临床应用与阅片要点
- 对于非创伤性急腹症的CT评估,可考虑采用个体化单期方案(延迟约67秒)以获取更高的血管强化和更清晰的脏器显示。
- 注意本研究为患者内比较,扫描间隔中位56天,可能影响对比剂增强的可比性。
局限性
- 两次扫描间隔中位56天(范围5-903天),间隔较长可能引入变异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To perform anintra-patient comparison betweena single-pass protocol (SP) and a portal venous phase (PVP) by means ofboth quantitative and qualitative analysis of image quality.
METHODS: Forty patients (31 M; 9F; aged 20-77 years; BMI 23 ± 4 Kg/m2) underwent both a SP and a PVP using a 64-rows multi-detector CT with a median interval time of 56 days (range5-903). All patients underwent i.v. bolus injection (2.0 cc/sec) of 1.7 cc/Kg of a non ionic iodinated contrast-media (370 mgI/ml) with scan delays of 67 ± 8 and 90 s for the SP and the PVP, respectively. Signal- (SNR) and contrast-to-noise ratios (CNR) were calculated for most visceral organs and for both abdominal aorta (AA) and main portal vein (MPV). For qualitative analysis, reproduction of abdominal viscera and vascular structures was blindly evaluated and inter-observer agreement calculated by the weighted Cohen k-analysis.
RESULTS: Attenuation values (H.U.) of AA (232 ± 53vs180 ± 36) and MPV (215 ± 39vs187 ± 42) were significantly (p < 0.001) higher in the SP than in PVP, respectively. At qualitative analysis, reproduction of mostabdominal viscerawas also significantly sharper (p < 0.001) with the SP than the PVPwith inter-observer agreement scores (k)ranging from 0.60 to 0.88 for all but one imaging criteria.
CONCLUSIONS: As the SP resulted in a significantly higher vascular enhancement and in a sharper reproduction of most abdominal viscera, it may be better suited than a PVP for the CT evaluation of non traumatic acute abdomen.
引用
- Camera L, Dell'Aversano-Orabona G, Gambardella M, et al. Tailored versus fixed scan delay in contrast-enhanced abdominal multi-detector CT: An intra-patient comparison of image quality. Eur J Radiol. 2021. PMID: 34509881. doi:10.1016/j.ejrad.2021.109914
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。