文献速递腹部儿科影像介入US

儿童慢性布加综合征介入治疗后2D剪切波弹性成像监测疗效的前瞻性研究

Utility of Hepatic 2D Shear-Wave Elastography in Monitoring Response to Image-Guided Intervention in Children With Chronic Budd-Chiari Syndrome: A Prospective Study.
PubMed 文献 · AJR Am J Roentgenol · 2021-09-29

本研究纳入32例慢性布加综合征儿童,在影像引导介入治疗前后用彩色多普勒超声和2D剪切波弹性成像测量肝硬度。介入后肝硬度显著下降,24小时降幅最大;疾病复发通常伴随肝硬度较前升高。肝硬度测量可能作为彩色多普勒超声的定量辅助手段监测复发。

要点

  • 介入后24小时肝硬度下降最明显,可作为早期疗效评估节点
  • 复发时肝硬度较前次测量升高,需结合彩色多普勒超声判断
  • 基线肝硬度与肝纤维化分期无显著相关,不宜单独用于分期

关键影像表现/征象

  • 9例(28.1%)患者在介入后平均4个月复发,其中1例复发患者24小时肝硬度(52.3 kPa)高于基线(44.2 kPa)。
  • 其余8例复发患者复发时肝硬度较前次介入后测量升高,中位绝对升高11.0 kPa(IQR 6.1-24.4 kPa)。

诊断标准与关键数值

  • 肝纤维化分期采用Metavir标准,由介入时肝活检确定。
  • 介入后24小时肝硬度与纤维化分期无显著相关(r=0.39,95%CI -0.11至0.73,P=0.11)。

临床应用与阅片要点

  • 介入后24小时肝硬度下降最明显,可作为早期疗效评估和后续比较的基线。
  • 随访中肝硬度较前次测量升高提示可能复发,应结合彩色多普勒超声综合判断。
  • 肝硬度不宜单独用于肝纤维化分期,需结合活检等参考标准。

局限性

  • 单中心前瞻性研究,样本量32例,复发患者仅9例。
  • 仅18例患者有肝活检纤维化分期资料。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND. Image-guided interventions for Budd-Chiari syndrome (BCS) reduce hepatic congestion, thereby reducing liver stiffness. Liver stiffness measurement (LSM) by means of ultrasound may provide a noninvasive marker for assessing treatment response. OBJECTIVE. The purpose of this study was to assess, with attention to changes in LSMs in patients with disease recurrence, the utility of 2D shear-wave elastography (SWE) for monitoring response to image-guided intervention in children with BCS. METHODS. This prospective study included children with chronic BCS and planned image-guided intervention. Color Doppler ultrasound (CDUS) and 2D SWE were performed at baseline; 24 hours, 1 month, and 3 months after intervention; and every 3 months thereafter or when recurrence was clinically suspected. Eighteen children underwent liver biopsy at intervention for fibrosis staging according to the Metavir criteria. Disease recurrence was diagnosed with CDUS. Statistical evaluation was performed by means of nonparametric tests. RESULTS. A total of 32 children (28 boys, four girls; mean age, 9 years; range, 3-14 years) were included. The median LSM at baseline was 43.7 (interquartile range [IQR], 33.0-65.4) kPa, at 24 hours was 22.5 (IQR, 16.8-32.0) kPa, at 1 month was 18.7 (IQR, 14.2-32.0) kPa, and at 3 months was 16.7 (IQR, 11.5-22.5) kPa (p = .001 for all postintervention time points vs baseline). Nine (28.1%) patients had a recurrence at a mean of 4 months after intervention. In one patient with recurrence, LSM was higher at 24 hours (52.3 kPa) than at baseline (44.2 kPa). In the other eight patients with recurrence, LSM was increased at recurrence compared with the prior postintervention LSM (median absolute increase, 11.0 [IQR, 6.1-24.4] kPa). Fibrosis stage was not significantly correlated with baseline LSM (r = 0.11 [95% CI, -0.37 to 0.54]; p = .51) or LSM 24 hours after intervention (r = 0.39 [95% CI, -0.11, 0.73]; p = .11). CONCLUSION. LSMs decreased significantly after image-guided intervention for chronic BCS in children, exhibiting a maximal decrease 24 hours after intervention. Disease recurrence was typically associated with an increase in LSM compared with the patient's prior measurement. CLINICAL IMPACT. LSM obtained with 2D SWE may serve as a useful quantitative adjunct to CDUS in monitoring children with chronic BCS for disease recurrence after percutaneous interventional treatment.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Dohare N, Madhusudhan KS, Malik R, et al. Utility of Hepatic 2D Shear-Wave Elastography in Monitoring Response to Image-Guided Intervention in Children With Chronic Budd-Chiari Syndrome: A Prospective Study. AJR Am J Roentgenol. 2021. PMID: 34585610. doi:10.2214/AJR.21.26547

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。