文献速递腹部CT

低管电压低对比剂方案联合混合迭代重建用于肝脏动态CT的诊断性能与图像质量

Diagnostic performance and image quality of low-tube voltage and low-contrast medium dose protocol with hybrid iterative reconstruction for hepatic dynamic CT.
PubMed 文献 · Br J Radiol · 2021-09-29

这项回顾性研究纳入424例患者,比较80kVp联合370mgI/kg对比剂与混合迭代重建、120kVp联合600mgI/kg对比剂与滤波反投影两种肝脏动态CT方案。结果显示80kVp方案在病灶检出率、HCC诊断能力(敏感度85.7-89.3%,特异度96.3-98.6%)及图像质量方面均非劣于120kVp方案,且碘剂量降低38.3%。

要点

  • 80kVp联合混合迭代重建可在肝脏动态CT中显著降低碘剂量(降幅38.3%)而不影响诊断性能。
  • 80kVp方案对HCC的敏感度85.7-89.3%、特异度96.3-98.6%,非劣于120kVp方案。
  • 两方案各期HCC-肝脏对比度无显著差异(p=0.309-0.705),图像质量非劣。

局限性

  • 回顾性研究设计
  • 单中心研究
  • 未报告读者间一致性数据

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the diagnostic performance and image quality of the low-tube voltage and low-contrast medium dose protocol for hepatic dynamic CT.

METHODS: This retrospective study was conducted between January and May 2018. All patients underwent hepatic dynamic CT using one of the two protocols: tube voltage, 80 kVp and contrast dose, 370 mgI/kg with hybrid iterative reconstruction or tube voltage, 120 kVp and contrast dose, 600 mgI/kg with filtered back projection. Two radiologists independently scored lesion conspicuity and image quality. Another radiologist measured the CT numbers of abdominal organs, muscles, and hepatocellular carcinoma (HCC) in each phase. Lesion detectability, HCC diagnostic ability, and image quality of the arterial phase were compared between the two protocols using the non-inferiority test. CT numbers and HCC-to-liver contrast were compared between the protocols using the Mann-Whitney U test.

RESULTS: 424 patients (70.5 ± 10.1 years) were evaluated. The 80-kVp protocol showed non-inferiority in lesion detectability and diagnostic ability for HCC (sensitivity, 85.7-89.3%; specificity, 96.3-98.6%) compared with the 120-kVp protocol (sensitivity, 91.0-93.3%; specificity, 93.6-97.3%) (p < 0.001-0.038). The ratio of fair image quality in the 80-kVp protocol also showed non-inferiority compared with that in the 120-kVp protocol in assessments by both readers (p < 0.001). HCC-to-liver contrast showed no significant differences for all phases (p = 0.309-0.705) between the two protocols.

CONCLUSION: The 80-kVp protocol with hybrid iterative reconstruction for hepatic dynamic CT can decrease iodine doses while maintaining diagnostic performance and image quality compared with the 120-kVp protocol.

ADVANCES IN KNOWLEDGE: The 80- and 120-kVp protocols showed equivalent hepatic lesion detectability, diagnostic ability for HCC, image quality, and HCC-to-liver contrast.The 80-kVp protocol showed a 38.3% reduction in iodine dose compared with the 120-kVp protocol.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Ichikawa S, Motosugi U, Shimizu T, et al. Diagnostic performance and image quality of low-tube voltage and low-contrast medium dose protocol with hybrid iterative reconstruction for hepatic dynamic CT. Br J Radiol. 2021. PMID: 34586900. doi:10.1259/bjr.20210601

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。