文献速递腹部MR

T1弛豫时间与MRE衍生硬度:评估慢性胰腺炎的新潜在影像生物标志物

T1 relaxation times and MR elastography-derived stiffness: new potential imaging biomarkers for the assessment of chronic pancreatitis.
PubMed 文献 · Abdom Radiol (NY) · 2021-09-15

本研究纳入19例轻度慢性胰腺炎、30例中重度慢性胰腺炎和35例健康对照,比较胰腺体积、T1 mapping、MRE和质子密度脂肪分数的诊断性能。T1 mapping和MRE在区分轻度慢性胰腺炎与对照时表现出很高的诊断性能(AUC分别为0.94和0.93),在诊断任何慢性胰腺炎时AUC分别达0.98和0.97。定量T1弛豫时间和MRE衍生硬度可能反映慢性胰腺炎早期纤维化改变。

要点

  • T1 mapping和MRE对轻度慢性胰腺炎的诊断性能很高,AUC分别达0.94和0.93。
  • T1 mapping和MRE在诊断任何慢性胰腺炎时AUC分别达0.98和0.97。
  • 胰腺体积、T1值、MRE硬度和PDFF在轻度CP、中重度CP和对照组间均有显著差异。

诊断标准与关键数值

  • T1 mapping区分轻度慢性胰腺炎与对照组:ROC-AUC 0.94,敏感度84%,特异度91%。
  • MRE区分轻度慢性胰腺炎与对照组:ROC-AUC 0.93,敏感度89%,特异度94%。
  • T1 mapping诊断任何慢性胰腺炎(从对照组中检出):ROC-AUC 0.98。
  • MRE诊断任何慢性胰腺炎(从对照组中检出):ROC-AUC 0.97。

临床应用与阅片要点

  • 对于怀疑轻度慢性胰腺炎而常规形态学改变不明显的患者,可考虑结合T1 mapping和MRE定量评估。
  • T1值和MRE硬度增高可能提示早期纤维化,阅片时需注意与正常胰腺的定量差异。
  • 胰腺体积和PDFF也可提供辅助信息,但诊断性能不如T1 mapping和MRE。

局限性

  • 单中心研究,样本量较小(轻度CP 19例,中重度CP 30例,对照35例)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Non-invasive imaging methods to detect morphological changes of the pancreas in patients with mild chronic pancreatitis (CP) are needed. This study aimed to compare magnetic resonance imaging-based parameters, pancreatic volume, T1 mapping, magnetic resonance elastography (MRE), and proton density fat fraction between CP patients and controls, and determine the diagnostic performance for diagnosing different stages of CP.

METHODS: Nineteen patients with mild CP (Cambridge grade 2 or less or recurring acute pancreatitis; n = 19), 30 with moderate/severe CP (Cambridge grade 3 and 4), and 35 healthy controls underwent pancreatic magnetic resonance imaging to assess the above mentioned magnetic resonance imaging-based parameters. The diagnostic performance of each parameter for detecting any mild and moderate/severe CP was determined using receiver operating characteristic analysis.

RESULTS: Pancreatic volume, T1 relaxation times, MRE-derived stiffness, and proton density fat fraction differed significantly between patients with mild CP, moderate/severe CP, and healthy controls (all p < 0.05). T1 mapping and MRE showed a very high diagnostic performance for distinguishing the mild CP group from the control group (T1 mapping: receiver operating characteristic area under the curve (ROC-AUC): 0.94; sensitivity: 84%; specificity: 91%, MRE: ROC-AUC: 0.93; sensitivity: 89%; specificity: 94%). T1 mapping and MRE also had the highest performance for diagnosing the presence of any CP from the control group (ROC-AUCs of 0.98 and 0.97, respectively).

CONCLUSION: Quantitative assessments of T1 relaxation time and MRE-derived stiffness had high performance in detecting mild CP and could probably reflect the early fibrotic changes in CP.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Steinkohl E, Olesen SS, Hansen TM, et al. T1 relaxation times and MR elastography-derived stiffness: new potential imaging biomarkers for the assessment of chronic pancreatitis. Abdom Radiol (NY). 2021. PMID: 34524501. doi:10.1007/s00261-021-03276-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。