文献速递腹部技术与安全CT

卷积神经网络特征在CT成像中对影像组学特征的稳健性与诊断能力

Feature Robustness and Diagnostic Capabilities of Convolutional Neural Networks Against Radiomics Features in Computed Tomography Imaging.
PubMed 文献 · Invest Radiol · 2022-01-01

该研究在体模和体内比较了CNN特征与影像组学特征对CT技术变化的稳健性。体模实验显示CNN特征的全局CCC高于98%,而影像组学特征最高仅36%;以变异系数≤0.2为稳健标准,CNN特征稳健比例为77%,影像组学为41%。回顾性分析中,49%的CNN特征可区分肝细胞癌与肝结肠癌转移。

要点

  • CNN特征对CT扫描参数变化的稳健性显著优于影像组学特征。
  • 以变异系数≤0.2为标准,CNN特征稳健比例77%,影像组学为41%。
  • 近半数CNN特征可区分肝细胞癌与肝结肠癌转移。

关键影像表现/征象

  • 所有体模的CNN特征全局CCC高于98%,影像组学特征最高CCC为36%。
  • CNN特征的平均特征方差和特征范围显著低于影像组学特征。
  • 示例体模的向量化激活图余弦相似度在所有扫描仪和参数变化下均大于0.98。

诊断标准与关键数值

  • 以变异系数≤0.2定义稳健特征,平均所有体模后,851个影像组学特征中346个(41%)稳健,256个CNN特征中196个(77%)稳健。
  • 在体内分析中,256个CNN特征中122个(49%)在肝细胞癌与肝结肠癌转移间有显著差异。

临床应用与阅片要点

  • 在CT定量分析中可优先考虑CNN特征以提高对扫描参数变化的稳健性。
  • 使用影像组学特征时需注意其受技术变化影响较大,必要时进行标准化或稳健性筛选。
  • CNN特征结合可视化方法可能辅助肿瘤实体鉴别,但需进一步验证。

局限性

  • 体内分析为回顾性研究,样本量有限(各30例)。
  • 特征稳定性对放射学图像预测临床结局的影响尚需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

MATERIALS AND METHODS: Imaging phantoms were scanned twice on 3 computed tomography scanners from 2 different manufactures with varying tube voltages and currents. Phantoms were segmented, and features were extracted using PyRadiomics and a pretrained CNN. After standardization the concordance correlation coefficient (CCC), mean feature variance, feature range, and the coefficient of variant were calculated to assess feature robustness. In addition, the cosine similarity was calculated for the vectorized activation maps for an exemplary phantom. For the in vivo comparison, the radiomics and CNN features of 30 patients with hepatocellular carcinoma (HCC) and 30 patients with hepatic colon carcinoma metastasis were compared.

RESULTS: In total, 851 radiomics features and 256 CNN features were extracted for each phantom. For all phantoms, the global CCC of the CNN features was above 98%, whereas the highest CCC for the radiomics features was 36%. The mean feature variance and feature range was significantly lower for the CNN features. Using a coefficient of variant ≤0.2 as a threshold to define robust features and averaging across all phantoms 346 of 851 (41%) radiomics features and 196 of 256 (77%) CNN features were found to be robust. The cosine similarity was greater than 0.98 for all scanner and parameter variations. In the retrospective analysis, 122 of the 256 CNN (49%) features showed significant differences between HCC and hepatic colon metastasis.

DISCUSSION: Convolutional neural network features were more stable compared with radiomics features against technical variations. Moreover, the possibility of tumor entity differentiation based on CNN features was shown. Combined with visualization methods, CNN features are expected to increase reproducibility of quantitative image representations. Further studies are warranted to investigate the impact of feature stability on radiological image-based prediction of clinical outcomes.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Ziegelmayer S, Reischl S, Harder F, et al. Feature Robustness and Diagnostic Capabilities of Convolutional Neural Networks Against Radiomics Features in Computed Tomography Imaging. Invest Radiol. 2022. PMID: 34524173. doi:10.1097/RLI.0000000000000827

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。