双能对比增强CT碘浓度与组织衰减作为胰腺癌术后局部复发早期检测的潜在定量参数
本研究纳入31例胰腺癌切除术后非特异性软组织形成患者,采用双能灌注CT计算碘浓度和120 kVp等效图像CT值,发现早期静脉期复发癌碘浓度和CT值均显著高于非特异性软组织,ROC分析提示碘浓度≥1.55 mg/ml(AUC=0.78,特异度1.0,敏感度0.53)和CT值≥57HU(AUC=0.82,特异度0.82,敏感度0.71)可作为鉴别参数。
要点
- 早期静脉期碘浓度≥1.55 mg/ml或CT值≥57HU提示局部复发可能。
- 复发癌早期静脉期碘浓度和CT值均显著高于非特异性术后软组织。
- 动脉期和胰腺期碘浓度有升高趋势但无统计学差异。
关键影像表现/征象
- 早期静脉期复发癌碘浓度显著高于非特异性软组织(1.47 mg/ml vs. 0.96 mg/ml,p=0.007)。
- 静脉期120 kVp等效图像复发癌CT值显著高于非特异性软组织(74HU vs 47HU,p=0.002)。
- 更早对比期碘浓度有升高趋势但无统计学显著性。
诊断标准与关键数值
- 早期静脉期碘浓度≥1.55 mg/ml诊断局部复发:AUC=0.78,特异度=1.0,敏感度=0.53。
- 静脉期120 kVp等效图像CT值≥57HU诊断局部复发:AUC=0.82,特异度=0.82,敏感度=0.71。
临床应用与阅片要点
- 对胰腺癌术后非特异性软组织形成,可加做双能CT并测量早期静脉期碘浓度或CT值辅助鉴别复发。
- 注意碘浓度阈值≥1.55 mg/ml特异度高但敏感度低,CT值阈值≥57HU敏感度和特异度较均衡。
- 动脉期和胰腺期碘浓度鉴别价值有限,应关注早期静脉期。
局限性
- 样本量小(31例),单中心研究。
- 仅纳入非特异性软组织形成患者,可能存在选择偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Due to the difficult differentiation from non-specific postoperative soft tissue formation (PSF), early diagnosis of pancreatic carcinoma recurrence remains challenging. Thus, we investigated the diagnostic potential of dual-energy (DE) contrast-enhanced CT.
METHOD: After potentially curative pancreatic carcinoma resection, 31 consecutive patients with PSF were examined via DE perfusion CT, acquiring 34 images (80 kVp/140 kVp) every 1.5 s, as the initial purpose of this study was evaluating CT-Perfusion. Corresponding time points of arterial, pancreatic, and early venous phase were calculated from bolus trigger times in prior conventional CT. Iodine and 120 kVp-equivalent images were calculated. Regions of interest were placed in each soft tissue formation. Diagnosis of local recurrence was confirmed by regular follow-up or histopathology.
RESULTS: Final diagnosis was local recurrence in 17 patients and non-specific PSF in 14 patients. Iodine concentrations in early venous phase were significantly higher in recurrent carcinoma than in non-specific PSF (1.47 mg/ml vs. 0.96 mg/ml, p = 0.007). In earlier contrast phases iodine concentrations tended to be higher, but not significantly. CT numbers in recurrent carcinoma in 120 kVp-equivalent images in venous phase were significantly higher, too (74HU vs 47HU, p = 0.002). ROC-curve analysis for iodine concentrations in early venous phase suggests a cut-off value of ≥ 1.55 mg/ml for local recurrence (AUC = 0.78, specificity = 1.0, sensitivity = 0.53) and for CT numbers in 120kVp-equivalent images a cut-off value of ≥ 57HU (AUC = 0.82, specificity = 0.82, sensitivity = 0.71).
CONCLUSION: In difficult cases, measuring iodine concentrations or CT numbers in PSF in (early) venous phase DECT could be a valuable additional parameter for differentiating local recurrence from non-specific PSF.
引用
- Mathy RM, Fritz F, Mayer P, et al. Iodine concentration and tissue attenuation in dual-energy contrast-enhanced CT as a potential quantitative parameter in early detection of local pancreatic carcinoma recurrence after surgical resection. Eur J Radiol. 2021. PMID: 34482176. doi:10.1016/j.ejrad.2021.109944
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。