人工智能分析横断面影像诊断肺动脉高压的诊断试验准确性:系统文献综述
该系统综述检索Medline、Embase和Web of Science(2020年7月1日),纳入3项回顾性观察研究,评估AI应用于横断面影像诊断获得性肺动脉高压的性能。心脏MRI模型诊断准确性高,最佳模型AUC=0.90(95%CI:0.85-0.93),敏感度89%、特异度81%;分类特发性PAH的AUC=0.97(95%CI:0.89-1.0),敏感度96%、特异度87%。基于CT的AI准确性较低,敏感度64.6%、特异度97.0%。
要点
- 心脏MRI的AI模型诊断PAH准确性高,最佳AUC达0.90,分类特发性PAH的AUC达0.97。
- CT-based AI敏感度较低(64.6%),特异度较高(97.0%),需更多研究验证。
- AI辅助横断面影像有望无创支持PAH早期诊断,减少诊断延迟。
核心结论
- 心脏MRI的自动化方法识别PAH已初现高诊断准确性,AI可无创辅助减少诊断延迟。
- 其他模态的解决方案有待加强,该领域研究显著不足。
研究设计与样本
- 系统综述,检索Medline、Embase和Web of Science(2020年7月1日),双盲两步法筛选,纳入3项回顾性观察研究。
- 研究质量采用QUADAS和CLAIM框架评估,叙事性综合遵循SWiM指南,注册号CRD42020196295,无资助。
诊断标准与关键数值
- 心脏MRI最佳模型诊断获得性PAH:AUC=0.90(95%CI:0.85-0.93),敏感度89%,特异度81%。
- 心脏MRI分类特发性PAH:AUC=0.97(95%CI:0.89-1.0),敏感度96%,特异度87%。
- CT-based AI诊断:敏感度64.6%,特异度97.0%。
临床应用与阅片要点
- 心脏MRI的AI模型可辅助无创识别PAH,但需注意研究均为回顾性、样本量有限。
- CT-based AI敏感度较低,阅片时不应单独依赖其排除PAH。
局限性
- 仅纳入3项回顾性观察研究,证据等级有限。
- 研究间异质性未行Meta分析,仅叙事性综合。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To undertake the first systematic review examining the performance of artificial intelligence (AI) applied to cross-sectional imaging for the diagnosis of acquired pulmonary arterial hypertension (PAH).
METHODS: Searches of Medline, Embase and Web of Science were undertaken on 1 July 2020. Original publications studying AI applied to cross-sectional imaging for the diagnosis of acquired PAH in adults were identified through two-staged double-blinded review. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies and Checklist for Artificial Intelligence in Medicine frameworks. Narrative synthesis was undertaken following Synthesis Without Meta-Analysis guidelines. This review received no funding and was registered in the International Prospective Register of Systematic Reviews (ID:CRD42020196295).
RESULTS: Searches returned 476 citations. Three retrospective observational studies, published between 2016 and 2020, were selected for data-extraction. Two methods applied to cardiac-MRI demonstrated high diagnostic accuracy, with the best model achieving AUC=0.90 (95% CI: 0.85-0.93), 89% sensitivity and 81% specificity. Stronger results were achieved using cardiac-MRI for classification of idiopathic PAH, achieving AUC=0.97 (95% CI: 0.89-1.0), 96% sensitivity and 87% specificity. One study reporting CT-based AI demonstrated lower accuracy, with 64.6% sensitivity and 97.0% specificity.
CONCLUSIONS: Automated methods for identifying PAH on cardiac-MRI are emerging with high diagnostic accuracy. AI applied to cross-sectional imaging may provide non-invasive support to reduce diagnostic delay in PAH. This would be helped by stronger solutions in other modalities.
ADVANCES IN KNOWLEDGE: There is a significant shortage of research in this important area. Early detection of PAH would be supported by further research advances on the promising emerging technologies identified.
引用
- Hardacre CJ, Robertshaw JA, Barratt SL, et al. Diagnostic test accuracy of artificial intelligence analysis of cross-sectional imaging in pulmonary hypertension: a systematic literature review. Br J Radiol. 2021. PMID: 34541861. doi:10.1259/bjr.20210332
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。