文献速递妇产影像儿科影像心血管US

二维斑点追踪超声心动图测量胎儿心肌形变:124例健康胎儿的纵向前瞻性队列研究

Fetal myocardial deformation measured with two-dimensional speckle-tracking echocardiography: longitudinal prospective cohort study of 124 healthy fetuses.
PubMed 文献 · Ultrasound Obstet Gynecol · 2022-04-06

前瞻性纵向队列研究纳入124例无并发症妊娠,自18-21周至分娩每4周行超声心动图,用二维斑点追踪超声心动图测量胎儿左右心室整体纵向应变(GLS)及应变率(GLSR),按孕周建立参考值并比较左右心室。共获592次左心室和566次右心室测量,两心室GLS和GLSR随孕周显著升高(即负值减小),右心室GLS各孕周均显著高于左心室。

要点

  • 胎儿GLS和GLSR参考值按孕周建立,两心室随孕周显著升高(负值减小)。
  • 各孕周右心室GLS均显著高于左心室(负值更小)。
  • 已获124例健康胎儿592次左心室和566次右心室GLS及GLSR测量。

核心结论

  • 获得二维斑点追踪超声心动图测量的胎儿GLS和GLSR参考值;两心室GLS和GLSR自中孕期至分娩显著升高;右心室GLS显著高于左心室;未来研究需评估所获参考值在临床评估妊娠并发症(如胎儿生长受限或心脏畸形)中的帮助。

研究设计与样本

  • 前瞻性纵向队列研究,124例无并发症妊娠、无畸形且生长适当的胎儿,自18-21周入组至分娩每4周行超声心动图获取四腔心切面,用二维斑点追踪超声心动图测量左右心室GLS和GLSR,采用贝叶斯混合效应模型按孕周计算参考值及上下5%预测限,用Wilcoxon符号秩检验比较左右心室GLS。

诊断标准与关键数值

  • 获得按孕周计算的胎儿左右心室GLS和GLSR参考值,附带上下5%预测限。
  • 共592次左心室和566次右心室GLS及GLSR测量,来自124例无并发症妊娠。

局限性

  • 未来研究需评估所获参考值在临床评估妊娠并发症(如胎儿生长受限或心脏畸形)中是否有帮助。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Two-dimensional speckle-tracking echocardiography (2D-STE) is a promising technique which allows assessment of fetal cardiac function, and can be used in the evaluation of cardiac and non-cardiac diseases in pregnancy. However, reliable fetal reference values for deformation parameters measured using 2D-STE are needed before it can be introduced into clinical practice. This study aimed to obtain reference values for fetal global longitudinal strain (GLS) and GLS rate (GLSR) measured using 2D-STE and compare right and left ventricular values.

METHODS: This was a prospective longitudinal cohort study of uncomplicated pregnancies that underwent echocardiography every 4 weeks from inclusion at 18-21 weeks until delivery to obtain four-chamber loops of the fetal heart. Left and right ventricular GLS and GLSR were measured using 2D-STE at each examination. Using Bayesian mixed-effects models, reference values with lower and upper 5% prediction limits were calculated according to gestational age. Right and left ventricular GLS values according to gestational age were compared using the Wilcoxon signed-rank test.

RESULTS: A total of 592 left ventricular and 566 right ventricular GLS and GLSR measurements were obtained from 124 women with uncomplicated pregnancy and non-anomalous, appropriately grown fetuses. Reference values were obtained for both fetal ventricles according to gestational week. GLS and GLSR values of both ventricles increased (i.e. became less negative) significantly during pregnancy. Right ventricular GLS values were significantly higher (i.e. less negative) than the respective left ventricular values at every gestational week.

CONCLUSIONS: Reference values were obtained for fetal GLS and GLSR measured using 2D-STE. GLS and GLSR values increased significantly for both ventricles from the second trimester until delivery. GLS values were significantly higher for the right ventricle compared with the left ventricle. Future studies are needed to assess whether the obtained reference values are helpful in clinical practice in the assessment of pregnancy complications, such as fetal growth restriction or cardiac anomaly. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. van Oostrum NHM, de Vet CM, Clur SB, et al. Fetal myocardial deformation measured with two-dimensional speckle-tracking echocardiography: longitudinal prospective cohort study of 124 healthy fetuses. Ultrasound Obstet Gynecol. 2022. PMID: 34558747. doi:10.1002/uog.24781

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。