文献速递腹部技术与安全CT

脾-主动脉密度比:预测重症监护患者短期预后的影像特征

Spleno-aortic radiodensity ratio - A distinctive imaging feature to predict short-term outcome in critical care unit.
PubMed 文献 · Eur J Radiol · 2021-08-28

脾-主动脉比值≤0.53预测短期死亡的敏感度为80.95%、特异度为96.74%,AUC为0.91,并在354例验证队列中得到验证。

要点

  • 门静脉期脾-主动脉CT密度比值≤0.53提示72小时内死亡风险高。
  • 该比值预测短期死亡的AUC达0.91,敏感度80.95%,特异度96.74%。
  • 脾与主动脉HU测量一致性好(ICC 0.92-0.99),便于推广。

局限性

  • 回顾性研究设计。
  • 单中心研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

INTRODUCTION: To investigate the value of contrast-enhanced CT findings - splenic and aortic radiodensities and their ratios (spleno-aortic ratio) - in predicting the prognosis of critical care unit patients (CCU).

METHODS: One hundred thirteen continuous CCU patients with an acute deterioration (Group A: 37 women, age: 67.2 ± 14.0 years) were included in the retrospective study. Radiodensities of the spleen and aorta were evaluated by two radiologists separately. The spleno-aortic ratio was calculated. Matthews correlation coefficient (MCC) was used in conjunction with receiver operating characteristic analysis (ROC) to assess if and which parameter was most suitable for short-term mortality prediction. The intra-class correlation coefficient assessed consensus across readers. To validate the results for the best predictor, a second cohort was evaluated (Group B: 354 CT scans).

RESULTS: The portal venous spleno-aortic ratio was best suited to predict 72-hour mortality (AUC = 0.91). A threshold ratio ≤0.53 predicted short-term mortality with a high sensitivity (80.95%) and specificity (96.74%, MCC = 0.79). The post-test probability was 85%, assuming a pre-test probability of 18.6% (72-hour mortality rate). ICCs of HU measurements in the aorta, spleen, and its ratios showed high interrater agreement (ICC: 0.92-0.99). In a control cohort, a threshold ratio ≤0.53 predicted CCU patientś outcome satisfactorily (SENS = 83.93%, SPEC = 97.65%, PPV = 87.00%, NPV = 97.00%).

CONCLUSIONS: The portal venous spleno-aortic ratio serves as a distinctive imaging feature to predict short-term mortality. For CCU patients with a cut-off portal venous spleno-aortic ratio ≤0.53, the risk of dying within three days after CT scan is approximately twenty times higher.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Fedders D, Hoxha G, Kaiser D, et al. Spleno-aortic radiodensity ratio - A distinctive imaging feature to predict short-term outcome in critical care unit. Eur J Radiol. 2021. PMID: 34479124. doi:10.1016/j.ejrad.2021.109939

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。