文献速递胸部MR

超极化氙气MRI肺量测定的可行性研究

Imaging Dynamic Expiration: Feasibility of MRI Spirometry Using Hyperpolarized Xenon Gas.
PubMed 文献 · Radiol Cardiothorac Imaging · 2021-08-05

前瞻性探索性研究纳入5名健康受试者,采用超极化129Xe吸入与高时间分辨率二维投影MRI,在用力呼气过程中以最短250毫秒间隔采集肺部图像,成功生成FEV1、FVC及FEV1/FVC的肺功能图。MRI-derived FEV1/FVC均值低于常规肺量计(0.52±0.03 vs 0.70±0.05,P<.01),可能反映129Xe选择性滞留。结论为超极化129Xe高时间分辨率MRI可成功成像用力呼气动作,并可行区域肺量测定图的推导。

要点

  • 超极化129Xe MRI可在用力呼气时以250毫秒间隔动态成像。
  • MRI推导的FEV1/FVC低于常规肺量计,需警惕129Xe滞留影响。
  • 吸入1 L 129Xe可降低仰卧位常规肺量计FEV1和FEV1/FVC。

核心结论

  • 超极化129Xe与高时间分辨率MRI可成功成像用力呼气动作,并可行区域肺量测定图的推导。
  • MRI推导的FEV1/FVC低于常规肺量计,可能反映129Xe的选择性滞留。

研究设计与样本

  • 前瞻性探索性研究,纳入5名健康受试者(年龄25-45岁,3名男性)。
  • 采用吸入超极化129Xe与快速二维投影MRI,在MR扫描仪内行用力呼气动作,图像采集间隔最短250毫秒。
  • 提取呼气开始(0秒)、呼气后1秒和呼气后6秒的容积校正肺图像,生成FEV1、FVC和FEV1/FVC肺图。
  • 对照常规肺量计在坐位呼吸室内空气、仰卧位呼吸室内空气、仰卧位呼吸室内空气与129Xe混合气三种条件下进行。
  • 统计采用配对t检验并以Bonferroni校正多重比较。

关键影像表现/征象

  • 呼气开始、呼气后1秒和呼气后6秒的容积校正肺图像用于生成FEV1、FVC和FEV1/FVC肺图。

诊断标准与关键数值

  • MRI推导的FEV1/FVC均值为0.52±0.03,低于常规肺量计的0.70±0.05(P<.01)。
  • 仰卧位吸入1 L 129Xe后常规肺量计FEV1为2.70±0.90,低于未吸入时的3.04±0.85(P<.01)。
  • 仰卧位吸入1 L 129Xe后常规肺量计FEV1/FVC为0.70±0.05,低于未吸入时的0.79±0.04(P<.01)。

临床应用与阅片要点

  • 阅片时需注意MRI推导的FEV1/FVC可能因129Xe滞留而低于常规肺量计,不宜直接等同。
  • 报告区域肺量测定图时应结合呼气动态图像和容积校正信息。

局限性

  • 探索性研究样本量小(5名健康受试者),未在患者中验证。
  • MRI推导FEV1/FVC低于常规肺量计,可能受129Xe选择性滞留影响。
  • 吸入1 L 129Xe本身对常规肺量计测值有负性影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To examine the feasibility of imaging-based spirometry using high-temporal-resolution projection MRI and hyperpolarized xenon 129 (129Xe) gas.

MATERIALS AND METHODS: In this prospective exploratory study, five healthy participants (age range, 25-45 years; three men) underwent an MRI spirometry technique using inhaled hyperpolarized 129Xe and rapid two-dimensional projection MRI. Participants inhaled 129Xe, then performed a forced expiratory maneuver while in an MR imager. Images of the lungs during expiration were captured in time intervals as short as 250 msec. Volume-corrected images of the lungs at expiration commencement (0 second), 1 second after expiration, and 6 seconds after expiration were extracted to generate forced expiratory volume in 1 second (FEV1), forced vital capacity (FVC), and FEV1/FVC ratio pulmonary maps. For comparison, participants performed conventional spirometry in the sitting position using room air, in the supine position using room air, and in the supine position using a room air and 129Xe mixture. Paired t tests with Bonferroni corrections for multiple comparisons were used for statistical analyses.

RESULTS: The mean MRI-derived FEV1/FVC value was lower in comparison with conventional spirometry (0.52 ± 0.03 vs 0.70 ± 0.05, P < .01), which may reflect selective 129Xe retention. A secondary finding of this study was that 1 L of inhaled 129Xe negatively impacted pulmonary function as measured by conventional spirometry (in supine position), which reduced measured FEV1 (2.70 ± 0.90 vs 3.04 ± 0.85, P < .01) and FEV1/FVC (0.70 ± 0.05 vs 0.79 ± 0.04, P < .01).

CONCLUSION: A forced expiratory maneuver was successfully imaged with hyperpolarized 129Xe and high-temporal-resolution MRI. Derivation of regional lung spirometric maps was feasible.Keywords: MR-Imaging, MR-Dynamic Contrast Enhanced, MR-Functional Imaging, Pulmonary, Thorax, Diaphragm, Lung, Pleura, Physics Supplemental material is available for this article. © RSNA, 2021.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Bewes J, Doganay O, Chen M, et al. Imaging Dynamic Expiration: Feasibility of MRI Spirometry Using Hyperpolarized Xenon Gas. Radiol Cardiothorac Imaging. 2021. PMID: 34498002. doi:10.1148/ryct.2021200571

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。