基于常规MRI与ADC图深度学习算法诊断儿童孤独症谱系障碍

Diagnosing autism spectrum disorder in children using conventional MRI and apparent diffusion coefficient based deep learning algorithms.
PubMed 文献 · Eur Radiol · 2021-09-04

本研究纳入151例ASD患儿和151例年龄匹配的TD对照,另用20例ASD和25例TD独立测试,构建7种深度学习模型(5个单序列模型、1个优势序列模型、1个全序列模型),部分嵌入注意力机制。基于FLAIR或ADC的单序列模型AUC达0.824~0.850;FLAIR+ADC组合的优势序列模型在验证集和独立测试集AUC分别升至0.873和0.876;带注意力机制的优势序列模型AUC、准确率、敏感度、特异度分别为0.898、84.4%、85.0%、84.0%。结论提示基于cMRI和ADC的深度学习模型有潜力区分ASD与TD。

要点

  • FLAIR与ADC联合的优势序列模型诊断性能优于任一单序列模型。
  • 注意力机制可进一步提升深度学习模型的诊断表现。
  • 独立测试集上优势序列模型AUC为0.876(无注意力)或0.898(带注意力)。

核心结论

  • 基于常规MRI和ADC图像的深度学习模型有潜力区分ASD患儿与TD对照。
  • FLAIR与ADC组合的优势序列模型诊断性能最佳,独立测试集AUC为0.876。
  • 嵌入注意力机制后优势序列模型AUC、准确率、敏感度、特异度分别为0.898、84.4%、85.0%、84.0%。

研究设计与样本

  • 研究为深度学习模型开发与验证研究,纳入151例ASD患儿和151例年龄匹配TD对照,数据分为训练集和验证集。
  • 独立测试集另纳入20例ASD患儿和25例TD对照。
  • 所有受试者均行脑部常规MRI和扩散加权成像检查,构建7种深度学习模型:5个单序列模型、1个优势序列模型和1个全序列模型,部分模型嵌入注意力机制模块。

诊断标准与关键数值

  • 基于FLAIR或ADC的单序列模型在验证集和独立测试集上最高AUC为0.824~0.850。
  • FLAIR与ADC组合的优势序列模型在验证集AUC为0.873,独立测试集AUC为0.876。
  • 全序列模型在验证集AUC为0.838,独立测试集AUC为0.836。
  • 带注意力机制的优势序列模型AUC为0.898,准确率84.4%,敏感度85.0%,特异度84.0%。

临床应用与阅片要点

  • 临床阅片时可关注FLAIR与ADC序列的组合信息,深度学习模型提示二者联合对ASD诊断价值更高。
  • 注意力机制可提升模型对关键特征的检测能力,未来或可辅助放射科医生提高ASD影像诊断的客观性。

局限性

  • 原文未明确报告研究局限性;样本量有限(ASD 151例、TD 151例,独立测试集ASD 20例、TD 25例),结论需更大样本验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To develop and validate deep learning (DL) methods for diagnosing autism spectrum disorder (ASD) based on conventional MRI (cMRI) and apparent diffusion coefficient (ADC) images.

METHODS: A total of 151 ASD children and 151 age-matched typically developing (TD) controls were included in this study. The data from these subjects were assigned to training and validation datasets. An additional 20 ASD children and 25 TD controls were acquired, whose data were utilized in an independent test set. All subjects underwent cMRI and diffusion-weighted imaging examination of the brain. We developed a series of DL models to separate ASD from TD based on the cMRI and ADC data. The seven models used include five single-sequence models (SSMs), one dominant-sequence model (DSM), and one all-sequence model (ASM). To enhance the feature detection of the models, we embed an attention mechanism module.

RESULTS: The highest AUC (0.824 ~ 0.850) was achieved when applying the SSM based on either FLAIR or ADC to the validation and independent test sets. A DSM using the combination of FLAIR and ADC showed an improved AUC in the validation (0.873) and independent test sets (0.876). The ASM also showed better diagnostic value in the validation (AUC = 0.838) and independent test sets (AUC = 0.836) compared to the SSMs. Among the models with attention mechanism, the DSM achieved the highest diagnostic performance with an AUC, accuracy, sensitivity, and specificity of 0.898, 84.4%, 85.0%, and 84.0% respectively.

CONCLUSIONS: This study established the potential of DL models to distinguish ASD cases from TD controls based on cMRI and ADC images.

KEY POINTS: • Deep learning models based on conventional MRI and ADC can be used to diagnose ASD. • The model (DSM) based on the FLAIR and ADC sequence achieved the best diagnostic performance with an AUC of 0.836 in the independent test sets. • The attention mechanism further improved the diagnostic performance of the models.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Guo X, Wang J, Wang X, et al. Diagnosing autism spectrum disorder in children using conventional MRI and apparent diffusion coefficient based deep learning algorithms. Eur Radiol. 2021. PMID: 34482428. doi:10.1007/s00330-021-08239-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。