快速MRI评估颈动脉与主动脉斑块的价值
本研究探讨两点Dixon快速MR血管成像(LAVA-Flex)检测颈动脉和主动脉斑块的效用。10例CEA患者中9例高信号病灶与富脂质核心/出血斑块病理对应;47例隐源性卒中患者中,LAVA-Flex诊断大斑块的敏感度95.5%、特异度88.0%。该技术有望快速诊断和评估主动脉源性卒中的关键风险斑块。
要点
- LAVA-Flex高信号可提示颈动脉斑块内脂质核心或出血。
- LAVA-Flex对主动脉大斑块(厚度≥4mm)诊断敏感度95.5%、特异度88.0%。
- 该技术可能有助于快速筛查主动脉源性卒中栓子来源。
关键影像表现/征象
- 10例CEA患者中9例(90.0%)LAVA-Flex显示颈动脉高信号病灶,病理对应富含大脂质核心和出血的斑块。
诊断标准与关键数值
- 以TEE检出主动脉大斑块(厚度≥4mm)为参考,LAVA-Flex诊断大斑块的敏感度为95.5%,特异度为88.0%。
临床应用与阅片要点
- 阅片时关注LAVA-Flex上颈动脉和胸主动脉的高信号病灶,可能提示富脂质核心或出血性斑块。
- 对隐源性卒中患者,可将LAVA-Flex作为快速筛查主动脉大斑块的手段,高信号病灶需结合TEE进一步确认。
- 注意高信号病灶并非均对应大斑块,需结合斑块厚度(如≥4mm)综合评估风险。
局限性
- 颈动脉部分样本量仅10例,结论需更大样本验证。
- 主动脉部分以TEE为参考标准,未与病理对照。
- 研究为单中心设计,可能存在选择偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Recently, various magnetic resonance imaging (MRI) modalities have been developed to easily detect carotid and aortic plaques, but these techniques are time-consuming and vulnerable to motion artifacts. We investigated the utility of a gradient echo MRI technique known as liver acquisition with volume acceleration flexible (LAVA-Flex) to detect carotid and aortic atherosclerotic plaques.
METHODS: Ten patients who underwent carotid endarterectomy (CEA) were assessed regarding the correspondence between LAVA-Flex findings and the histopathology of excised carotid plaques. In addition, 47 patients with cryptogenic ischemic stroke underwent LAVA-Flex and transesophageal echocardiography (TEE) for detection of embolic sources in the thoracic aorta. We analyzed the relationship between the thickness of the aortic plaque measured by TEE and the presence of high-intensity lesions on LAVA-Flex.
RESULTS: Nine of 10 patients (90.0%) who underwent CEA showed a high-intensity carotid lesion on LAVA-Flex, which corresponded pathologically to plaques containing large lipid cores and hemorrhage. Twenty-four (51.1%) of 47 cryptogenic stroke patients showed a high-intensity lesion in the thoracic aorta on LAVA-Flex; of these, 21 (87.5%) also demonstrated a large plaque (thickness ≥4 mm) on TEE. Twenty-two (95.7%) of 23 patients without a high-intensity lesion on LAVA-Flex demonstrated no large plaque on TEE. LAVA-Flex had a sensitivity of 95.5% and a specificity of 88.0% in patients with large plaques.
CONCLUSION: This study showed that LAVA-Flex successfully detected carotid and aortic plaques. This imaging technique may be useful to rapidly diagnose and evaluate carotid and aortic plaques, which are critical risk factors for aortogenic stroke.
引用
- Morihara K, Nakano T, Mori K, et al. Usefulness of rapid MR angiography using two-point Dixon for evaluating carotid and aortic plaques. Neuroradiology. 2021. PMID: 34559244. doi:10.1007/s00234-021-02812-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。