儿童颅内肿瘤分级:IVIM与DKI是否优于传统DWI
纳入54例经组织学证实的儿童颅内肿瘤患者,比较传统DWI、体素内不相干运动(IVIM)及扩散峰度成像(DKI)参数与病理特征的相关性。高低级别肿瘤间ADC、D、Dk值及K值差异均有统计学意义(P<.001),但各参数鉴别高低级别肿瘤的AUC差异无统计学意义(P>.05),提示IVIM与DKI参数分级效能与传统DWI相仿。
要点
- K值在高级别肿瘤升高,ADC、D、Dk值降低,均可辅助分级。
- 各扩散参数AUC约0.86–0.90,IVIM/DKI并不优于传统DWI。
- 扩散指标与细胞密度及Ki-67相关,可间接反映肿瘤增殖活性。
核心结论
- IVIM与DKI衍生参数在预测儿童颅内肿瘤分级方面与传统DWI性能相仿。
- 扩散指标可能反映儿童颅内肿瘤的细胞密度与Ki-67。
- 高级别肿瘤ADC、D、Dk值更低而K值更高(均P<.001)。
研究设计与样本
- 单中心研究,纳入54例经组织学证实的儿童颅内肿瘤患者。
- 患者均行传统DWI、IVIM及DKI检查,以组织病理学为参考标准。
- 测量肿瘤实性成分的ADC、D、D*、f、K及Dk参数,并行细胞密度、Ki-67及微血管密度测定。
- 采用Mann-Whitney U检验比较高低级别肿瘤,并行Spearman相关与ROC分析。
关键影像表现/征象
- 高级别儿童颅内肿瘤的ADC、D、Dk值低于低级别肿瘤(均P<.001)。
- 高级别肿瘤的K值高于低级别肿瘤(P<.001)。
诊断标准与关键数值
- ADC、D、Dk与细胞密度及Ki-67呈负相关(r=-0.548至-0.740,均P<.05)。
- K值与细胞密度及Ki-67呈正相关(r=0.674–0.802,均P<.05)。
- 鉴别高低级别肿瘤的AUC:ADC为0.901、D为0.894、Dk为0.863、K为0.885。
- 各参数AUC差异无统计学意义(均P>.05)。
临床应用与阅片要点
- 可在常规DWI基础上补充IVIM/DKI参数辅助儿童颅内肿瘤分级。
- 注意各参数分级效能相近,不应期待IVIM/DKI明显优于ADC。
- 扩散参数可提示细胞密度与增殖活性,但需结合病理确认。
局限性
- 原文未明确报告研究局限性。
- 单中心、样本量较小(54例),结果外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: An accurate evaluation of the World Health Organization grade is critical in pediatric intracranial tumors. Our aim was to explore the correlations between parameters derived from conventional DWI, intravoxel incoherent motion, and diffusional kurtosis imaging with histopathologic features to evaluate the accuracy of diffusion parameters for grading of pediatric intracranial tumors.
MATERIALS AND METHODS: Fifty-four pediatric patients with histologically proved intracranial tumors who underwent conventional DWI, intravoxel incoherent motion, and diffusional kurtosis imaging were recruited. The conventional DWI (ADC), intravoxel incoherent motion (pure diffusion coefficient [D], pseudodiffusion coefficient [D*], perfusion fraction [f], diffusional kurtosis imaging [K], and diffusion coefficient [Dk]) parameters in the solid component of tumors were measured. The cellularity, Ki-67, and microvessel density were measured. These parameters were compared between the low- and high-grade pediatric intracranial tumors using the Mann-Whitney U test. Spearman correlations and receiver operating characteristic analysis were performed.
RESULTS: The ADC, D, and Dk values were lower, whereas the K value was higher in high-grade pediatric intracranial tumors than in low-grade tumors (all, P < .001). The K value showed positive correlations (r = 0.674-0.802; all, P < .05), while ADC, D, and Dk showed negative correlations with cellularity and Ki-67 (r = -0.548 to -0.740; all, P < .05). The areas under the curve of ADCVOI, DVOI, DkVOI, and KVOI were 0.901, 0.894, 0.863, and 0.885, respectively, for differentiating high- from low-grade pediatric intracranial tumors. The area under the curve difference in grading pediatric intracranial tumors was not significant (all, P > .05).
CONCLUSIONS: Intravoxel incoherent motion- and diffusional kurtosis imaging-derived parameters have similar performance compared with conventional DWI in predicting pediatric intracranial tumor grade. The diffusion metrics may potentially reflect tumor cellularity and Ki-67 in pediatric intracranial tumors.
引用
- She D, Lin S, Guo W, et al. Grading of Pediatric Intracranial Tumors: Are Intravoxel Incoherent Motion and Diffusional Kurtosis Imaging Superior to Conventional DWI? AJNR Am J Neuroradiol. 2021. PMID: 34556474. doi:10.3174/ajnr.A7270
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。