儿童肾动脉狭窄:CTA与DSA对比验证研究
结果显示CTA在主肾动脉 level 敏感度85.7%、特异度91.5%、准确率88.9%,但2/3级分支敏感度仅14.3%。CTA有效剂量中位数2.2 mSv,低于DSA的13.7 mSv。
要点
- CTA在主肾动脉狭窄诊断中敏感度85.7%、特异度91.5%,阴性预测值90.1%。
- 2/3级分支狭窄CTA敏感度仅14.3%,阴性预测值82.7%,需谨慎评估。
- CTA中位有效剂量2.2 mSv,显著低于DSA的13.7 mSv。
核心结论
- CTA在主肾动脉水平诊断儿童肾动脉狭窄具有高敏感度和特异度,且辐射剂量低于既往假设,可用于低中风险患者的诊断工具及高风险患者的筛查和治疗计划工具。
研究设计与样本
- 仅纳入DSA前6个月内行CTA的患儿,由两名儿科放射科医生独立盲法阅片评估主肾动脉及2/3级分支狭窄,以DSA为参考标准。
- 计算敏感度、特异度、准确率及有效辐射剂量,采用Kappa统计评估阅片者间一致性。
诊断标准与关键数值
- CTA检测肾动脉狭窄总体敏感度85.7%、特异度91.5%、准确率88.9%。
- 主肾动脉水平阅片者间一致性中等(k=0.73),2/3级分支几乎完美(k=0.98)。
- 主肾动脉水平阴性预测值90.1%,2/3级分支阴性预测值82.7%,但2/3级分支敏感度仅14.3%。
- CTA中位有效剂量2.2 mSv(范围0.6-6.3),DSA有效剂量13.7 mSv。
临床应用与阅片要点
- 对于疑似儿童肾动脉狭窄,CTA可作为低中风险患者的诊断工具,高风险患者的筛查和治疗计划工具。
- 阅片时需注意CTA对2/3级分支狭窄敏感度低,阴性结果不能完全排除分支病变。
- 报告应明确描述主肾动脉及分支狭窄情况,并提示CTA辐射剂量较低。
局限性
- 仅纳入DSA前6个月内行CTA的患儿,可能存在选择偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Renal artery stenosis is an important cause of hypertension in children, accounting for 5-10% of cases. When suspected, noninvasive imaging options include ultrasound (US), computed tomography (CT) angiography and magnetic resonance (MR) angiography. However, digital subtraction angiography (DSA) remains the gold standard.
OBJECTIVE: To investigate the accuracy and inter-reader reliability of CT angiography in children with suspected renal artery stenosis.
MATERIALS AND METHODS: This is a retrospective study of patients suspected of having renal artery stenosis evaluated by both CT angiography and DSA between 2008 and 2019 at a tertiary pediatric hospital. Only children who underwent CT angiography within 6 months before DSA were included. CT angiography studies were individually reviewed by two pediatric radiologists, blinded to clinical data, other studies and each other's evaluation, to determine the presence of stenosis at the main renal artery and 2nd- and 3rd-order branches. The sensitivity, specificity and accuracy were calculated using DSA as the reference. The effective radiation dose for CT angiography and DSA was also calculated. Kappa statistics were used to assess inter-reader agreement.
RESULTS: Seventy-four renal units were evaluated (18 girls, 19 boys). The patients' median age was 8 years (range: 1-21 years). Overall, CT angiography was effective in detecting renal artery stenosis with a sensitivity of 85.7%, specificity of 91.5% and accuracy of 88.9%. There was moderate inter-reader agreement at the main renal artery level (k=0.73) and almost perfect inter-reader agreement at the 2nd/3rd order (k=0.98). However, the sensitivity at the 2nd- and 3rd-order level was lower (14.3%). CT angiography provided excellent negative predictive value for evaluating renal artery stenosis at the main renal artery level (90.1%) and at the 2nd- or 3rd-order branches (82.7%). The median effective dose of CT angiography studies was 2.2 mSv (range: 0.6-6.3) while the effective dose of DSA was 13.7 mSv.
CONCLUSION: CT angiography has high sensitivity and specificity at the main renal artery level with a lower radiation dose than previously assumed. Therefore, it can be used as a diagnostic tool in patients with low to medium risk of renal artery stenosis, and as a screening and treatment planning tool in patients at high risk.
引用
- Fleury AS, Durand RE, Cahill AM, et al. Validation of computed tomography angiography as a complementary test in the assessment of renal artery stenosis: a comparison with digital subtraction angiography. Pediatr Radiol. 2021. PMID: 34374838. doi:10.1007/s00247-021-05145-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。