超声评估踝关节骨关节炎的诊断效能:与X线、锥形束CT及症状的比较
研究纳入51例踝关节骨关节炎患者,以锥形束CT为金标准,比较超声与常规X线对踝关节骨关节炎改变的诊断效能,并评估影像表现与WOMAC症状的相关性。结果显示超声对积液/滑膜炎、骨赘和软骨损伤的敏感度较低至中等,特异度较高,总体诊断效能仅为中等,与X线相当;影像表现与症状仅呈弱相关。
要点
- 超声对踝关节积液/滑膜炎敏感度仅45%,特异度90%,易漏诊。
- 超声检出前踝骨赘敏感度78%、特异度79%,内侧和外侧骨赘敏感度更低。
- 超声对距骨软骨损伤敏感度仅18%,但特异度高达97%。
核心结论
- 超声检测踝关节骨关节炎的能力仅为中等,与常规X线相当。
- 影像学表现与WOMAC症状评分仅呈弱相关。
研究设计与样本
- 前瞻性诊断效能研究,纳入51例踝关节骨关节炎患者,均在同一天接受超声、常规X线和锥形束CT检查。
- 以锥形束CT为金标准,由一名对其它模态结果不知情的放射科医生评估所有影像。
- WOMAC症状问卷在48例患者中可用。
关键影像表现/征象
- 超声评估踝关节积液/滑膜炎、骨赘、距骨软骨损伤和腱鞘炎,并与X线和锥形束CT相应表现比较。
诊断标准与关键数值
- 超声检出踝关节积液/滑膜炎的敏感度45%、特异度90%。
- 超声检出前踝骨赘的敏感度78%、特异度79%;内侧骨赘敏感度39%、特异度83%;外侧骨赘敏感度54%、特异度100%。
- 超声检出距骨软骨损伤的敏感度18%、特异度97%。
临床应用与阅片要点
- 超声对踝关节骨关节炎的阴性结果不能排除病变,尤其对软骨损伤和内侧骨赘敏感度低。
- 超声高特异度可用于确认病变,但阴性时需结合X线或锥形束CT。
局限性
- 单中心小样本研究,仅一名放射科医生评估影像,未报告重复性。
- WOMAC问卷仅48例可用,症状关联分析样本量有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To determine the diagnostic performance of ultrasonography (US) for evaluation of the ankle joint osteoarthritic (OA) changes. Cone-beam computed tomography (CT) was used as the gold standard and US performance was compared with conventional radiography (CR). As a secondary aim, associations between the imaging findings and ankle symptoms were assessed.
METHODS: US was performed to 51 patients with ankle OA. Every patient had prior ankle CR and underwent cone-beam CT during the same day as US examination. On US, effusion/synovitis, osteophytes, talar cartilage damage, and tenosynovitis were evaluated. Comparison to respective imaging findings on CR and cone-beam CT was then performed. Single radiologist blinded to other modalities assessed all the imaging studies. Symptoms questionnaire, the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), was available for 48 patients.
RESULTS: US detected effusion/synovitis of the talocrural joint with 45% sensitivity and 90% specificity. For the detection of anterior talocrural osteophytes, US sensitivity was 78% and specificity 79%. For the medial talocrural osteophytes, they were 39 and 83%, and for the lateral talocrural osteophytes 54 and 100%, respectively. Considering cartilage damage of the talus, US yielded a low sensitivity of 18% and high specificity of 97%. Overall, the performance of US was only moderate and comparable to CR. The imaging findings showed only weak associations with ankle symptoms.
CONCLUSIONS: The ability of US to detect ankle OA is only moderate. Interestingly, performance of CR also remained moderate. The associations between imaging findings and WOMAC score seem to be weak in ankle OA.
引用
- Nevalainen MT, Pitkänen MM, Saarakkala S, et al. Diagnostic Performance of Ultrasonography for Evaluation of Osteoarthritis of Ankle Joint: Comparison With Radiography, Cone-Beam CT, and Symptoms. J Ultrasound Med. 2021. PMID: 34378811. doi:10.1002/jum.15803
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。