高b值DWI对甲状腺微结节的诊断价值:与高分辨率超声的对比研究
回顾性纳入80例经病理证实的单发甲状腺微结节(≤1.0 cm)患者,均行高分辨率超声和b值2000 s/mm²的DWI。DWI联合rADC诊断甲状腺微结节的敏感度、特异度、准确度分别为83.7%、89.2%、86.3%,AUC为0.91(95%CI 0.84-0.97);高分辨率超声分别为100%、62.16%、82.5%。高b值DWI对实性甲状腺微结节的诊断效能优于高分辨率超声,可提高诊断特异度、减少过度诊断和不必要的活检或手术。
要点
- 高b值DWI联合rADC诊断甲状腺微结节的特异度为89.2%,高于高分辨率超声的62.16%。
- 高分辨率超声诊断敏感度达100%,但特异度较低,易导致过度诊断。
- DWI的ADC定量分析可作为甲状腺微结节评估的补充手段,提高诊断特异度。
核心结论
- 高b值DWI对实性甲状腺微结节的诊断效能优于高分辨率超声。
- DWI及其ADC定量分析可加入甲状腺微结节的评估,以提高诊断特异度、减少过度诊断并避免不必要的活检或手术。
研究设计与样本
- 回顾性研究,纳入80例经病理证实的单发甲状腺微结节(≤1.0 cm)患者,均行高分辨率超声和b值2000 s/mm²的DWI。
- 采用组内相关系数评估观察者内和观察者间一致性,Kruskal-Wallis检验分析ADC定量值与甲状腺结节亚组的关系,Cohen's kappa分析评估DWI和高分辨率超声特征的观察者间一致性。
- 采用受试者工作特征曲线评估甲状腺恶性结节的诊断效能,McNemar检验和Kappa检验比较两种影像方法的敏感度、特异度和准确度。
诊断标准与关键数值
- DWI联合rADC(ADCmin与ADCn比值)诊断甲状腺微结节的敏感度为83.7%,特异度为89.2%,准确度为86.3%,AUC为0.91(95%CI 0.84-0.97)。
- 高分辨率超声诊断甲状腺微结节的敏感度为100%,特异度为62.16%,准确度为82.5%。
- 共纳入80例患者,包括43个恶性微结节和37个良性微结节。
临床应用与阅片要点
- 对于实性甲状腺微结节,可在高分辨率超声评估基础上补充高b值DWI及ADC定量分析,以提高诊断特异度。
- 高分辨率超声敏感度高但特异度较低,需注意其可能导致的过度诊断。
- DWI联合rADC有助于减少不必要的活检或手术,但需结合临床和其他影像特征综合判断。
局限性
- 本研究为回顾性研究,样本量有限(80例),可能存在选择偏倚。
- 仅纳入单发甲状腺微结节且均经病理证实,结论外推至多发结节或未病理证实结节时需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: This study aims to compare the diagnostic performance of two imaging methods for thyroid nodules ≤1.0 cm and reduce unnecessary overdiagnosis.
METHODS: A retrospective study was conducted on 80 patients with pathologically confirmed solitary thyroid micronodules underwent both high-resolution ultrasound (HRUS) and High b-value (2000 s/mm2) diffusion weighted imaging (DWI). Intra- and interobserver agreement (Intraclass correlation coefficient) was followed by Kruskal-Wallis test to detect whether the quantitative apparent diffusion coefficient (ADC) and thyroid nodule subgroups were related. Cohen's kappa analysis was applied to assess the interobserver consistency of DWI and HRUS characteristics. The receiver operating characteristic curves were adopted for evaluating the diagnostic performance of thyroid malignancy. The sensitivity, specificity, and accuracy of the two imaging methods were compared using the McNemar's test and Kappa test.
RESULTS: A total of 80 patients were included, consisting of 43 malignant and 37 benign micronodules. The sensitivity, specificity and accuracy of DWI combined with rADC (ADCmin to ADCn ratio) for the diagnosis of thyroid micronodules were 83.7%, 89.2% and 86.3%, respectively. The area under the curve (AUC) was 0.91 (95% confidence interval [CI]: 0.84-0.97). The sensitivity, specificity and accuracy of HRUS diagnosis were 100%, 62.16% and 82.5%, respectively.
CONCLUSION: High b-value DWI is superior to HRUS for evaluating the diagnostic performance of solid thyroid micronodules. DWI and its ADC quantitative analysis could be added to the evaluation of thyroid micronodules to improve the specificity of diagnosis, reduce overdiagnosis and avoid unnecessary biopsies or surgeries.
引用
- Zhang J, Fu WX, Li WP, et al. Diagnostic value of thyroid micronodules with high b-value diffusion weighted imaging: Comparative study with high-resolution ultrasound. Eur J Radiol. 2021. PMID: 34450516. doi:10.1016/j.ejrad.2021.109912
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。