文献速递甲状腺与浅表US

五种甲状腺结节超声分类系统诊断准确性的前瞻性比较研究

Diagnostic Accuracy of Five Different Classification Systems for Thyroid Nodules: A Prospective, Comparative Study.
PubMed 文献 · J Ultrasound Med · 2021-08-09

该前瞻性研究纳入1010个转诊活检的甲状腺结节,用五种超声分类系统(Kwak TI-RADS、EU TI-RADS、K TI-RADS、ACR TI-RADS、ATA)分类,以细胞学和组织病理学为参考标准。最终939个结节中恶性73个(7.8%)。ACR TI-RADS对所有结节敏感性最高(94.5%),Kwak TI-RADS特异性最高;对1-3cm结节,ATA和ACR TI-RADS敏感性最高。

要点

  • ACR TI-RADS对所有结节敏感性最高(94.5%),Kwak TI-RADS最低(69%)。
  • Kwak TI-RADS特异性最高,最善于排除良性结节。
  • 对1-3cm结节,ATA(97.8%)和ACR TI-RADS(91.3%)敏感性最高。

诊断标准与关键数值

  • ACR TI-RADS对所有结节敏感性最高(94.5%),Kwak TI-RADS最低(69%)。
  • 排除<1cm和>3cm结节后,ATA敏感性最高(97.8%),ACR TI-RADS第二(91.3%)。
  • 除Kwak TI-RADS(fair agreement)外,其余分类系统间具有substantial agreement。

临床应用与阅片要点

  • ACR TI-RADS可作为高敏感性筛查工具,减少漏诊恶性结节。
  • Kwak TI-RADS特异性高,可用于排除良性结节,但敏感性低需注意漏诊风险。
  • 对1-3cm结节,ATA和ACR TI-RADS敏感性高,适合作为风险分层首选。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the diagnostic performance of five different thyroid ultrasound classification systems, and determine which system is optimal for evaluating thyroid nodules and reducing the unnecessary biopsy rate.

METHODS: In this prospective study, 1,010 nodules referred for biopsy during a 2-year period were classified using five classification systems: the Kwak Thyroid Imaging Reporting and Data System (Kwak TI-RADS), the European TI-RADS (EU TI-RADS, the Korean TI-RADS (K TI-RADS), the American College of Radiology TI-RADS (ACR TI-RADS), and the American Thyroid Association (ATA) classification. After fine needle aspiration biopsy, all classifications were compared for all nodules and also particularly for nodules sized 1-3 cm. Sensitivity, specificity, and interobserver agreement were evaluated for each classification system.

RESULTS: Of the 939 nodules (after exclusion of Bethesda 3 nodules) finally classified according to the surgical histopathology and cytology results, 73 (7.8%) were malignant and 866 nodules were benign (92.2%). The sensitivity was highest (94.5%) for the ACR TI-RADS and lowest for the Kwak TI-RADS (69%). After exclusion of small (<1 cm) and large nodules (>3 cm); while sensitivity was highest for ATA (97.8%), ACR TI-RADS was the second best classification (91.3%). There was substantial agreement among all classification systems except the Kwak TI-RADS (fair agreement).

CONCLUSIONS: The ACR TI-RADS was the most sensitive ultrasound risk stratification system for all nodules, while the Kwak TI-RADS was the most specific, ie, the most capable of excluding benign nodules based on the combined cytological and histopathological results. ATA and ACR-TIRADS were the most sensitive classification systems for nodules 1 to 3 cm in size. The ACR TI-RADS had higher sensitivity than the Bethesda classification system when compared according to the histopathological results.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Orhan Soylemez UP, Gunduz N. Diagnostic Accuracy of Five Different Classification Systems for Thyroid Nodules: A Prospective, Comparative Study. J Ultrasound Med. 2021. PMID: 34370333. doi:10.1002/jum.15802

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。