文献速递乳腺乳腺X线

虚拟临床试验比较二维乳腺摄影、数字乳腺断层合成与合成二维成像的癌症检出

Virtual clinical trial to compare cancer detection using combinations of 2D mammography, digital breast tomosynthesis and synthetic 2D imaging.
PubMed 文献 · Eur Radiol · 2021-07-30

该虚拟临床试验在166例无癌症病例中数字插入细微钙化簇和肿块,比较单独DM、DM联合DBT、SM联合DBT三种方案,由5位乳腺阅片者定位并评分。结果显示肿块检出DBT方案显著优于单独DM,钙化簇检出各方案无显著差异;DBT图像上病变可见性高于DM和SM。

要点

  • 肿块检出DBT联合方案优于单独DM,钙化簇检出各方案无显著差异。
  • DBT图像上钙化簇和肿块可见性均高于DM和SM图像。
  • 结果支持在所用成像技术下,采集DBT时可不常规附加DM。

核心结论

  • 肿块检出DBT方案显著优于单独DM,钙化簇检出各方案无显著差异。
  • DBT图像上病变可见性高于DM和SM图像。
  • 结果支持在所用成像技术下可不常规附加DM采集。

研究设计与样本

  • 虚拟临床试验,166例无癌症病例,其中104例数字插入细微钙化簇和肿块。
  • 三组:单独DM、DM联合DBT、SM联合DBT;5位乳腺阅片者定位病变并评分。
  • 计算JAFROC FoM和LDF,比较DBT与SM、DM图像上病变可见性。

关键影像表现/征象

  • DBT图像上钙化簇和肿块可见性均高于DM和SM图像。
  • 肿块在DBT方案上FoM和LDF显著优于单独DM(p < 0.001)。
  • 钙化簇各方案FoM和LDF无显著差异(p > 0.075)。

诊断标准与关键数值

  • 肿块:DBT方案FoM和LDF较单独DM显著改善(p < 0.001)。
  • 钙化簇:各方案FoM和LDF无显著差异(p > 0.075)。
  • 钙化簇LDF在DM联合DBT与SM联合DBT间无显著差异(p = 0.075)。

临床应用与阅片要点

  • 阅片时DBT对肿块检出优势明显,应充分利用DBT断层图像。
  • 钙化簇检出各方案无显著差异,SM联合DBT可作为替代方案。
  • 依据所用成像技术,可考虑不常规附加DM采集。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study was designed to compare the detection of subtle lesions (calcification clusters or masses) when using the combination of digital breast tomosynthesis (DBT) and synthetic mammography (SM) with digital mammography (DM) alone or combined with DBT.

METHODS: A set of 166 cases without cancer was acquired on a DBT mammography system. Realistic subtle calcification clusters and masses in the DM images and DBT planes were digitally inserted into 104 of the acquired cases. Three study arms were created: DM alone, DM with DBT and SM with DBT. Five mammographic readers located the centre of any lesion within the images that should be recalled for further investigation and graded their suspiciousness. A JAFROC figure of merit (FoM) and lesion detection fraction (LDF) were calculated for each study arm. The visibility of the lesions in the DBT images was compared with SM and DM images.

RESULTS: For calcification clusters, there were no significant differences (p > 0.075) in FoM or LDF. For masses, the FoM and LDF were significantly improved in the arms using DBT compared to DM alone (p < 0.001). On average, both calcification clusters and masses were more visible on DBT than on DM and SM images.

CONCLUSIONS: This study demonstrated that masses were detected better with DBT than with DM alone and there was no significant difference (p = 0.075) in LDF between DM&DBT and SM&DBT for calcifications clusters. Our results support previous studies that it may be acceptable to not acquire digital mammography alongside tomosynthesis for subtle calcification clusters and ill-defined masses.

KEY POINTS: • The detection of masses was significantly better using DBT than with digital mammography alone. • The detection of calcification clusters was not significantly different between digital mammography and synthetic 2D images combined with tomosynthesis. • Our results support previous studies that it may be acceptable to not acquire digital mammography alongside tomosynthesis for subtle calcification clusters and ill-defined masses for the imaging technology used.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Mackenzie A, Thomson EL, Mitchell M, et al. Virtual clinical trial to compare cancer detection using combinations of 2D mammography, digital breast tomosynthesis and synthetic 2D imaging. Eur Radiol. 2021. PMID: 34331118. doi:10.1007/s00330-021-08197-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。