计算机辅助诊断系统在不同经验放射科医生乳腺病变鉴别诊断中的附加价值
本研究纳入192名女性266个乳腺肿块,评估基于深度学习算法的S-Detect系统在区分良恶性乳腺肿块及减少不必要活检中的价值。四位不同经验放射科医生(1、4、9、20年)分别在有和无S-Detect结果下分析超声图像。结果显示,低年资放射科医生参考S-Detect后诊断准确率、特异度、阳性预测值、阴性预测值及曲线下面积显著提高(P < .05),不必要活检率显著降低(44.4% vs 32.7%,P = .006;36.8% vs 28.2%,P = .033),而高年资放射科医生无显著改善(P > .05)。
要点
- S-Detect可显著提高低年资放射科医生乳腺超声诊断准确率及降低不必要活检率。
- 高年资放射科医生(9年、20年)参考S-Detect后诊断效能无显著改善。
- 低年资放射科医生对S-Detect的依赖程度更高,改变诊断决策的病例数更多。
局限性
- 单中心研究,样本量有限(192名女性266个肿块)。
- 未报告S-Detect本身的敏感度、特异度及AUC等诊断效能数值。
- 未描述乳腺肿块的具体影像特征及良恶性参考标准。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the value of the computer-aided diagnosis system, S-Detect (based on deep learning algorithm), in distinguishing benign and malignant breast masses and reducing unnecessary biopsy based on the experience of radiologists.
METHODS: From February 2018 to March 2019, 266 breast masses in 192 women were included in our study. Ultrasound (US) examination, including S-Detect technique, was performed by the radiologist with about 10 years of clinical experience in breast US imaging. US images were analyzed by four other radiologists with different experience in breast imaging (radiologists 1, 2, 3, and 4 with 1, 4, 9, and 20 years, respectively) according to their clinical experience (with and without the results of S-Detect). Diagnostic capabilities and unnecessary biopsy of radiologists and radiologists combined with S-Detect were compared and analyzed.
RESULTS: After referring to the results of S-Detect, the changes made by less experienced radiologists were greater than experienced radiologists (benign or malignant, 44 vs 22 vs 14 vs 2; unnecessary biopsy, 34 vs 25 vs 10 vs 5). When combined with S-Detect, less experienced radiologists showed significant improvement in accuracy, specificity, positive predictive value, negative predictive value, and area under curve (P < .05), but not for experienced radiologists (P > .05). Similarly, the unnecessary biopsy rate of less experienced radiologists decreased significantly (44.4% vs 32.7%, P = .006; 36.8% vs 28.2%, P = .033), but not for experienced radiologists (P > .05).
CONCLUSIONS: Less experienced radiologists rely more on S-Detect software. And S-Detect can be an effective decision-making tool for breast US, especially for less experienced radiologists.
引用
- Wei Q, Zeng SE, Wang LP, et al. The Added Value of a Computer-Aided Diagnosis System in Differential Diagnosis of Breast Lesions by Radiologists With Different Experience. J Ultrasound Med. 2021. PMID: 34432320. doi:10.1002/jum.15816