B型超声、彩色多普勒与弹性成像在乳腺癌诊断中的价值:CD-CONFIRM多中心研究1351个乳腺实性肿块结果
CD-CONFIRM多中心研究评估彩色多普勒(CD)诊断标准及CD与弹性成像的关系,纳入13家机构1351个乳腺肿块(恶性639、良性712)。单独B型超声敏感度很高,加用CD后敏感度无显著提高,但特异度从61.2%显著提高至69.2%(p<0.0001);B型+CD联合弹性成像后特异度进一步从72.8%显著提高至79.0%(p<0.0001)。研究表明CD诊断标准有用,且CD与弹性成像相互独立。
要点
- B型超声加彩色多普勒可显著提高乳腺肿块诊断特异度(61.2%→69.2%)。
- B型+CD联合弹性成像可进一步显著提高特异度(72.8%→79.0%)。
- CD与弹性成像为独立诊断方法,联合使用可互补提高特异度。
诊断标准与关键数值
- 单独B型超声敏感度很高,加用CD后敏感度无显著提高。
- B型超声特异度61.2%,加用CD后特异度显著提高至69.2%(p<0.0001)。
- B型+CD联合弹性成像后特异度从72.8%显著提高至79.0%(p<0.0001)。
临床应用与阅片要点
- 在B型超声基础上加用彩色多普勒可提高诊断特异度,减少良性病变误判。
- 联合弹性成像可进一步独立提高特异度,提示多模态评估有助于乳腺肿块良恶性鉴别。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The usefulness of color Doppler ultrasound (CD) in distinguishing between benign and malignant breast lesions remains controversial. Our prior study, the Japan Association of Breast and Thyroid Sonology (JABTS) BC-04 study (malignant: 839, benign: 569), found CD was useful in breast cancer diagnosis, and we developed CD diagnostic criteria. The first aim of the current study (the CD-CONFIRM study) was to evaluate the usefulness of the CD diagnostic criteria. The second aim was to evaluate the relationship between CD and elastography. We evaluated ultrasound images of breast masses from 13 institutions (malignant: 639, benign: 712). While the sensitivity of B-mode alone was very high and was not significantly improved with CD, the specificity was significantly improved with CD (61.2%-69.2%, p < 0.0001). Furthermore, the specificity of the combination of B-mode and CD improved significantly with the addition of elastography (72.8%-79.0%, p < 0.0001). This study found that the CD criteria are useful, and CD and elastography are independent.
引用
- Watanabe T, Yamaguchi T, Okuno T, et al. Utility of B-Mode, Color Doppler and Elastography in the Diagnosis of Breast Cancer: Results of the CD-CONFIRM Multicenter Study of 1351 Breast Solid Masses. Ultrasound Med Biol. 2021. PMID: 34456085. doi:10.1016/j.ultrasmedbio.2021.07.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。