乳腺组织微结构特征:DWI与ARFI弹性成像头对头比较及临床意义
该回顾性研究纳入60例BI-RADS 3-5乳腺病变患者,头对头比较DWI与ARFI弹性成像对乳腺病变的鉴别诊断效能,以组织学为参考标准。结果显示ARFI与DWI的AUC分别为0.822和0.871(p=0.48),两者定量参数呈显著负相关(ρ=-0.501,p<0.001),联合应用未提高诊断效能。
要点
- ARFI与DWI对乳腺良恶性病变的鉴别效能相似,AUC无显著差异。
- SWVmax与ADCmean呈显著负相关,提示两者提供重叠的诊断信息。
- 联合ARFI与DWI未改善诊断效能,日常可优先选择任一方法。
局限性
- 回顾性研究设计
- 单中心研究
- 样本量较小(60例)
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Head-to-head comparison of Diffusion Weighted Imaging (DWI) and Acoustic Radiation Force Impulse (ARFI) elastography regarding the characterization of breast lesions in an assessment setting.
METHOD: Patients undergoing an ultrasound examination including ARFI and an MRI protocol including DWI for the characterization of a BI-RADS 3-5 breast lesion between 06/2013 and 10/2016 were eligible for inclusion in this retrospective, IRB-approved study. 60 patients (30-84 years, median 50) with a median lesion size of 16 mm (range 5-55 mm) were included. The maximum shear wave velocity (SWVmax) and mean apparent diffusion coefficient (ADCmean) for each lesion were retrospectively evaluated by a radiologist experienced in the technique. Histology was the reference standard. Diagnostic performances of ARFI and DWI were assessed using ROC curve analysis. Spearman's rank correlation coefficient and multivariate logistic regression were used to investigate the independence of both tests regarding their diagnostic information to distinguish benign from malignant lesions.
RESULTS: Corresponding areas under the ROC curve for differentiation of benign (n = 16) and malignant (n = 49) lesions were 0.822 (ARFI) and 0.871 (DWI, p-value = 0.48). SWVmax and ADCmean values showed a significant negative correlation (ρ = -0.501, p-value < 0.001). In multivariate analysis, combination of ARFI and DWI did not improve the results of each single modality, thus no significant independent diagnostic information was present.
CONCLUSION: Significant correlation between quantitative findings of ARFI and DWI in breast lesions exists. Thus, ARFI provides similar diagnostic information as a DWI-including protocol of an additional "problem-solving" MRI for the characterization of a sonographically evident breast lesion, improving the immediate patient management in the assessment setting.
引用
- Kapetas P, Clauser P, Milos RI, et al. Microstructural breast tissue characterization: A head-to-head comparison of Diffusion Weighted Imaging and Acoustic Radiation Force Impulse elastography with clinical implications. Eur J Radiol. 2021. PMID: 34438330. doi:10.1016/j.ejrad.2021.109926
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。