文献速递乳腺技术与安全US

超声彩色多普勒闪烁伪像用于识别乳腺和腋窝活检标记物

Using Ultrasound Color Doppler Twinkling to Identify Biopsy Markers in the Breast and Axilla.
PubMed 文献 · Ultrasound Med Biol · 2021-08-16

该研究对12种活检标记物体外行彩色多普勒超声成像,按0-4分共识评分闪烁程度,并用三维干涉术测量表面粗糙度。结果显示Cork、Q和Vision三种标记物体外闪烁评分≥3,仅Cork在离体和尸体组织中评分为4;表面粗糙度与闪烁评分呈正相关(rho=0.33,95%CI [-0.48至0.84])。低彩色量程和频率可优化闪烁,而对彩色量程和频率变化不敏感是闪烁信心的最特异定性预测指标。

要点

  • 闪烁伪像有助于超声识别活检标记物,尤其腋窝等困难部位。
  • Cork标记物体外、离体和尸体组织中均显示最显著闪烁(评分4)。
  • 对彩色量程和频率变化不敏感是判断闪烁信心的最特异指标。

关键影像表现/征象

  • Cork、Q和Vision三种标记物体外闪烁评分≥3。
  • 仅Cork标记物在离体和尸体组织中闪烁评分为4。
  • 较低彩色量程和彩色频率可优化闪烁伪像显示。
  • 对彩色量程和频率变化不敏感是闪烁信心的最特异定性预测指标。

诊断标准与关键数值

  • 闪烁程度采用0(无闪烁)至4(显著闪烁)共识评分。
  • 表面粗糙度与闪烁评分正相关(rho=0.33,95%CI [-0.48至0.84])。

临床应用与阅片要点

  • 可尝试用彩色多普勒闪烁伪像辅助定位乳腺和腋窝活检标记物。
  • 调整较低彩色量程和频率以优化闪烁显示。
  • 闪烁不随彩色量程和频率变化而改变时,诊断信心更高。

局限性

  • 样本量仅12种标记物,相关性置信区间宽。
  • 研究为体外实验,离体和尸体组织验证有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

In breast radiology, ultrasound detection of biopsy markers or clips for localization purposes is often challenging, especially in the axilla. The purpose of this research was to test the hypothesis that the surface roughness of biopsy clips would elicit a twinkling signature on color Doppler, making them more readily identifiable by ultrasound. Ultrasound color Doppler imaging of 12 biopsy markers was performed and consensus scoring of the degree of twinkling (0 [no twinkling] to 4 [exuberant twinkling]) was obtained for each of the markers. The surface roughness characteristics of the markers were measured using 3-D coherence scanning interferometry. The 3 markers scoring at least 3 for twinkling in vitro were cork, Q and Vision. Of these 3 markers, only the cork marker scored a 4 ex vivo and in cadaveric tissue. Surface roughness metrics demonstrated a positive estimated correlation with the twinkling scores (rho = 0.33, 95% CI = [-0.48 to 0.84]). Of the 12 markers tested, the markers that twinkled corresponded to surface roughness measured with non-contact 3-D optical imaging. Qualitatively, lower color scales and color frequencies optimized twinkling, but the most specific qualitative predictor of confidence in twinkling was insensitivity to changes in color scale and color frequency values.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Lee CU, Hesley GK, Uthamaraj S, et al. Using Ultrasound Color Doppler Twinkling to Identify Biopsy Markers in the Breast and Axilla. Ultrasound Med Biol. 2021. PMID: 34412903. doi:10.1016/j.ultrasmedbio.2021.04.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。