经阴道超声检测深部子宫内膜异位症宫旁受累的诊断准确性:系统综述与meta分析
该系统综述与meta分析评估经阴道超声(TVS)以腹腔镜为参考标准检测宫旁深部子宫内膜异位症的准确性,纳入4项研究共560例患者。汇总敏感度为31%(95%CI 10-64%),特异度为98%(95%CI 95-99%),阳性似然比18.5(95%CI 8.8-38.9),阴性似然比0.70(95%CI 0.46-1.06),诊断比值比26(95%CI 10-68)。TVS特异度高但敏感度低,TVS上疑似宫旁深部子宫内膜异位病灶的显示可显著提高阳性后概率。
要点
- TVS检测宫旁深部子宫内膜异位症敏感度低(31%),阴性不能排除受累。
- TVS特异度高达98%,阳性发现对诊断宫旁受累有重要价值。
- TVS显示疑似宫旁病灶时,阳性后概率显著提高。
核心结论
- TVS检测宫旁深部子宫内膜异位症具有高特异度(98%)但低敏感度(31%),阳性结果有助于诊断,阴性结果不能排除宫旁受累。
关键影像表现/征象
- TVS上显示疑似宫旁深部子宫内膜异位病灶时,阳性后概率显著提高。
诊断标准与关键数值
- TVS检测宫旁深部子宫内膜异位症的汇总敏感度31%(95%CI 10-64%),特异度98%(95%CI 95-99%)。
- 阳性似然比18.5(95%CI 8.8-38.9),阴性似然比0.70(95%CI 0.46-1.06),诊断比值比26(95%CI 10-68)。
- 手术时宫旁深部子宫内膜异位症的平均患病率为18%。
临床应用与阅片要点
- TVS发现宫旁疑似深部子宫内膜异位病灶时应提示宫旁受累可能,因特异度高,阳性发现对诊断有重要价值。
- TVS未见宫旁病灶时不能排除宫旁深部子宫内膜异位症,因敏感度低,需结合临床及其他检查综合评估。
局限性
- 纳入研究数量少(仅4项),异质性高。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the accuracy of transvaginal sonography (TVS) for detecting parametrial deep endometriosis, using laparoscopy as the reference standard.
METHODS: A search was performed in PubMed/MEDLINE and Web of Science for studies evaluating TVS for detecting parametrial involvement in women with suspected deep endometriosis, as compared with laparoscopy, from January 2000 to December 2020. The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was used to evaluate the quality of the studies. Pooled sensitivity, specificity and positive and negative likelihood ratios for TVS in the detection of parametrial deep endometriosis were calculated, and the post-test probability of parametrial deep endometriosis following a positive or negative test was determined.
RESULTS: The search identified 134 citations. Four studies, comprising 560 patients, were included in the analysis. The mean prevalence of parametrial deep endometriosis at surgery was 18%. Overall, the pooled estimated sensitivity, specificity and positive and negative likelihood ratios of TVS in the detection of parametrial deep endometriosis were 31% (95% CI, 10-64%), 98% (95% CI, 95-99%), 18.5 (95% CI, 8.8-38.9) and 0.70 (95% CI, 0.46-1.06), respectively. The diagnostic odds ratio was 26 (95% CI, 10-68). Heterogeneity was high. Visualization of a lesion suspected to be parametrial deep endometriosis on TVS increased significantly the post-test probability of parametrial deep endometriosis.
CONCLUSION: TVS has high specificity but low sensitivity for the detection of parametrial deep endometriosis. © 2021 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Guerriero S, Martinez L, Gomez I, et al. Diagnostic accuracy of transvaginal sonography for detecting parametrial involvement in women with deep endometriosis: systematic review and meta-analysis. Ultrasound Obstet Gynecol. 2021. PMID: 34358386. doi:10.1002/uog.23754
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。