文献速递妇产影像US

剪切波弹性成像评估宫颈癌前病变:一种新的诊断工具

Evaluation of Pre-malignant Lesions of the Uterine Cervix by Shear Wave Elastography: A New Diagnostic Tool.
PubMed 文献 · Ultrasound Med Biol · 2021-08-08

前瞻性观察性研究纳入96名非妊娠女性,采用二维剪切波弹性成像测量宫颈中线矢状面0.5 cm深度处(宫颈管、前后唇)的硬度。宫颈癌前病变组(PIL,48例)的剪切波速度和硬度均显著高于无病变组(NPIL,48例),且高级别鳞状上皮内病变(HSIL)组高于持续低级别鳞状上皮内病变(LSIL-persistent)组。以速度3.25 m/s为阈值鉴别HSIL与无病变,敏感度62.5%、特异度75.5%、AUC 73.4%。

要点

  • 宫颈剪切波弹性成像测量速度与硬度可区分癌前病变与正常宫颈。
  • HSIL组宫颈硬度显著高于持续LSIL组。
  • 速度3.25 m/s为鉴别HSIL与无病变的最佳阈值,AUC 73.4%。

关键影像表现/征象

  • PIL组与NPIL组在所有评估深度的剪切波速度和硬度均有显著差异(速度4.1 m/s vs 3.0 m/s,硬度58.6 kPa vs 34.5 kPa,p < 0.001)。
  • HSIL组与持续LSIL组之间剪切波速度和硬度亦有显著差异(速度4.9 m/s vs 3.2 m/s,硬度76.1 kPa vs 38.0 kPa,p < 0.001)。

诊断标准与关键数值

  • 剪切波速度鉴别HSIL与无病变的AUC为73.4%(95%CI:63.1-83.7)。
  • 最佳速度阈值为3.25 m/s,敏感度62.5%(95%CI:47.3-76.0),特异度75.5%(95%CI:60.4-87.1)。

临床应用与阅片要点

  • 可在宫颈中线矢状面0.5 cm深度处(宫颈管、前后唇)测量剪切波速度和硬度,辅助区分癌前病变与正常宫颈。
  • 速度≥3.25 m/s提示HSIL可能,但敏感度与特异度中等,需结合临床和其他检查综合判断。

局限性

  • 研究为单中心前瞻性观察性设计,样本量有限(共96例)。
  • HSIL组仅26例,持续LSIL组仅22例,亚组样本量较小。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The objective of the study was to evaluate the difference in the stiffness between a healthy cervix (no pre-invasive lesions [NPILs]) and a cervix with a pre-invasive lesion (PIL). In the PIL group, we determined whether there was a difference in stiffness between the cervix with persistent low-grade lesions (>2 y, LSIL-persistent) and that with high-grade lesions (HSILs). Evaluation was performed using 2-D shear-wave elastography (SWE) in the midsagittal-plane of the uterine cervix (UC) at 0.5 cm (cervical canal, anterior and posterior cervical lips). In this prospective observational study (consecutive series), we evaluated 96 non-pregnant women: a group with PIL (LSIL-persistent, 22 cases; HSIL, 26 cases) with indications for cervical conization (48 cases) and a group without UC pathology (NPIL, 48 cases). Although we did not observe statistically significant differences (SSDs) in epidemiological characteristics, we did find an SSD in the speed and stiffness between the PIL versus NPIL groups at all evaluated depths (speed: 4.1 m/s vs 3.0 m/s, stiffness: 58.6 and 34.5kPa in the PIL and NPIL groups, respectively, p < 0.001). An SSD in speed and stiffness (speed: 4.9 m/s vs. 3.2 m/s, and stiffness: 76.1 and 38.0 kPa) between the HSIL (26 cases) and LSIL-persistent (22 cases) groups, respectively, was also detected (p < 0.001). The area under the curve of speed differentiation between a cervix with HSILs and without lesions was 73.4% (95% confidence interval [CI]: 63.1-83.7), and the best cutoff of speed was 3.25 m/s (sensitivity = 62.5%, 95% CI: 47.3-76.0), with a specificity of 75.5% (95% CI: 60.4-87.1).

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Sainz JA, Castro L, Romo JM, et al. Evaluation of Pre-malignant Lesions of the Uterine Cervix by Shear Wave Elastography: A New Diagnostic Tool. Ultrasound Med Biol. 2021. PMID: 34376298. doi:10.1016/j.ultrasmedbio.2021.06.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。