单方向弥散加权成像可作为评估胎儿胼胝体的简易补充序列
本研究前瞻性纳入67例胼胝体正常胎儿和35例疑似胼胝体发育不全胎儿,比较单方向DWI与HASTE/TrueFISP序列对胎儿胼胝体的显示效果和对比度。结果显示单方向DWI的「良好」显示比例和对比度均更高,且联合HASTE/TrueFISP的诊断准确率(97.1%)高于单独HASTE/TrueFISP(74.3%)。
要点
- 单方向DWI显示胎儿胼胝体的良好可见比例和对比度均优于HASTE/TrueFISP。
- 单方向DWI联合HASTE/TrueFISP诊断胼胝体发育不全准确率97.1%,高于单独HASTE/TrueFISP的74.3%。
- 疑似胼胝体发育不全时,单方向DWI矢状面可测量胼胝体长度和面积辅助诊断。
关键影像表现/征象
- 单方向DWI上胼胝体「良好」可见(评分≥3分,几乎或完全可见)的比例高于HASTE/TrueFISP(p<0.0001)。
- 单方向DWI的平均对比度高于TrueFISP和HASTE(均p<0.0001)。
- 部分性胼胝体发育不全组和完全性胼胝体发育不全组的胼胝体长度和面积均显著低于正常组(长度p<0.001,面积p=0.001或p=0.018)。
诊断标准与关键数值
- 可见度评分≥3分定义为「良好」可见,即胼胝体几乎或完全可见。
- 单方向DWI联合HASTE/TrueFISP诊断胼胝体发育不全的准确率为97.1%(34/35),高于单独HASTE/TrueFISP的74.3%(26/35)(p=0.013)。
临床应用与阅片要点
- 在胎儿MRI中可加扫单方向DWI作为补充序列,以提高胼胝体的显示和发育不全的诊断准确率。
- 疑似胼胝体发育不全时,可在单方向DWI矢状面上测量胼胝体长度和面积,并与正常参考值比较。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To explore the feasibility of single-direction diffusion-weighted imaging (DWI) for assessing the fetal corpus callosum (CC).
METHODS: This prospective study included 67 fetuses with normal CC and 35 fetuses suspected with agenesis of the corpus callosum (ACC). The MR protocols included HASTE, TrueFISP, and single-direction DWI. Two radiologists independently evaluated the optimal visibility and the contrast ratio (CR) of the normal fetal CC. The Chi-squared test or Fisher's exact test was used to compare the proportions of "good" visibility (score ≥ 3, and the CC was almost/entirely visible) between single-direction DWI and HASTE/TrueFISP. The CR difference between single-direction DWI and HASTE/TrueFISP was detected using the paired t-test. The diagnostic accuracies were determined by comparison with postnatal imaging. In fetuses suspected of ACC, we measured and compared the length and area of the mid-sagittal CC in the single-direction DWI images.
RESULTS: The proportion of "good" visibility in single-direction DWI was higher than that in HASTE/TrueFISP, with p < 0.0001. The mean CR from single-direction DWI was also higher than that of TrueFISP and HASTE (both with p < 0.0001). The diagnostic accuracy of the single-direction DWI combined with HASTE/TrueFisp (97.1%, 34/35) was higher than that of the Haste/TrueFISP (74.3%, 26/35) (p = 0.013). The length and area of the PACC (p < 0.001, p = 0.001, respectively) and HCC (p < 0.001, p = 0.018, respectively) groups were significantly lower than those of the normal group.
CONCLUSIONS: The single-direction DWI is feasible in displaying fetal CC and can be a complementary sequence in diagnosing ACC.
KEY POINTS: • We suggest a simple method for the display of the fetal CC. • The optimal visibility and contrast ratio from single-direction DWI were higher than those from HASTE and TrueFISP. • The diagnostic accuracy of the single-direction DWI combined with HASTE/TrueFISP sequences (97.1%, 34/35) was higher than that of the Haste/TrueFISP (74.3%, 26/35).
引用
- Sun C, Zhang X, Chen X, et al. Single-direction diffusion-weighted imaging may be a simple complementary sequence for evaluating fetal corpus callosum. Eur Radiol. 2021. PMID: 34331117. doi:10.1007/s00330-021-08176-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。