文献速递泌尿生殖腹部MR

ESUR评分系统诊断前列腺癌包膜外侵犯的Meta分析

Diagnostic performance of ESUR scoring system for extraprostatic prostate cancer extension: A meta-analysis.
PubMed 文献 · Eur J Radiol · 2021-08-16

本Meta分析纳入10项研究共1698例患者,评估ESUR评分系统检测前列腺癌包膜外侵犯(EPE)的诊断效能。汇总敏感度0.71(95%CI 0.61-0.80),特异度0.76(95%CI 0.67-0.84),AUC 0.80(95%CI 0.77-0.84)。Cutoff值(ESUR≥3 vs ≥4,P=0.02)和恶性肿瘤率(<40% vs ≥40%,P=0.04)是异质性显著影响因素。

要点

  • ESUR评分诊断EPE敏感度0.71、特异度0.76、AUC 0.80,属中等诊断效能。
  • Cutoff值(≥3 vs ≥4)和恶性肿瘤率是异质性显著影响因素。
  • 使用直肠内线圈和3.0T高场强未显示额外获益。

局限性

  • 敏感度和特异度均存在显著异质性(I2分别为86.5%和91.6%)。
  • 纳入研究间cutoff值和恶性肿瘤率存在差异,可能影响汇总结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: We aimed to evaluate the diagnostic performance of the European Society of Urogenital Radiology (ESUR) scoring system for detection of extraprostatic extension (EPE) in prostate cancer (PCa) by performing a meta-analysis.

MATERIALS AND METHODS: A literature search of MEDLINE, EMBASE, Cochrane Library, Web of Science, and Google Scholar was performed to identify relevant studies from January 2012 to December 2020. We included diagnostic accuracy studies using ESUR scoring system for detection of EPE, and with prostatectomy histopathological results as the reference standard. Quality assessment was performed with the Quality Assessment of Diagnostic Accuracy Studies-2 tool. The summary estimates of sensitivity and specificity were pooled using bivariate random-effects modeling. We conducted multiple subgroup analyses and meta-regression to explore varied clinical settings.

RESULTS: 10 studies with a total of 1698 participants were included in this meta-analysis. Pooled sensitivity and specificity were 0.71 (95% CI 0.61-0.80) and 0.76 (95% CI 0.67-0.84), respectively, with the area under ROC of 0.80 (95% CI 0.77-0.84). The Higgins I2 statistics demonstrated substantial heterogeneity in both sensitivity (I2 = 86.5%) and specificity (I2 = 91.6%), meta-regression revealed that the cutoff values (ESUR score ≥ 3 vs. ESUR score ≥ 4, P = 0.02) and malignancy rate (<40% vs. ≥40%, P = 0.04) were significant factors responsible for heterogeneity. Using endorectal coil and higher field strength (3.0 T) showed no additional benefit for EPE detection.

CONCLUSION: The evidence available for ESUR scoring system tends to show moderate diagnostic performance for detection of EPE, and the cutoff values (P = 0.02) and malignancy rate (P = 0.04) were significant factors contributed to the heterogeneity.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Li W, Dong A, Hong G, et al. Diagnostic performance of ESUR scoring system for extraprostatic prostate cancer extension: A meta-analysis. Eur J Radiol. 2021. PMID: 34416449. doi:10.1016/j.ejrad.2021.109896

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。