分数阶微积分扩散模型与双参数VI-RADS评估膀胱尿路上皮癌分期与分级
FROC参数联合用于分期的特异度85%、准确率78%、AUC 0.782,用于分级的敏感度89%、特异度86%、准确率88%、AUC 0.892,均优于ADC;FROC联合双参数VI-RADS使AUC从0.859提升至0.931。
要点
- FROC模型参数D、μ在MIBC中显著低于NMIBC(p=0.001),D、β、μ在高级别肿瘤中均显著降低(p≤0.011)。
- FROC三参数联合对肿瘤分级AUC 0.892,优于ADC;与双参数VI-RADS联合可将AUC从0.859提升至0.931。
- 高b值DWI FROC模型有助于无创区分膀胱癌肌层浸润与组织学分级。
核心结论
- 高b值DWI的FROC模型可用于区分NMIBC与MIBC以及膀胱肿瘤分级,FROC参数联合双参数VI-RADS可提升诊断性能。
研究设计与样本
- DWI采集16个b值(0-3600 s/mm²),采用FROC模型分析得到D、β、μ参数。
- 以ROC分析比较FROC参数单独及联合、ADC以及基于T2WI和DWI的双参数VI-RADS的诊断效能。
诊断标准与关键数值
- 区分NMIBC与MIBC:D、μ在MIBC组显著低于NMIBC组(各p=0.001)。
- 肿瘤分级:D、β、μ在高级别肿瘤均显著低于低级别肿瘤(p≤0.011)。
- FROC三参数联合区分NMIBC与MIBC:特异度85%、准确率78%、AUC 0.782;分级:敏感度89%、特异度86%、准确率88%、AUC 0.892。
- FROC参数D(AUC 0.842)和μ(AUC 0.857)用于分级优于ADC(AUC 0.804),p≤0.046。
- FROC三参数联合区分NMIBC与MIBC的特异度85%优于ADC的67%(p=0.031)。
临床应用与阅片要点
- 阅片时可利用高b值DWI FROC模型参数辅助判断膀胱肿瘤肌层浸润及分级。
- FROC参数联合双参数VI-RADS可提高诊断效能,尤其改善区分NMIBC与MIBC的特异度。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the feasibility of high b-value diffusion-weighted imaging (DWI) for distinguishing non-muscle-invasive bladder cancer (NMIBC) from muscle-invasive bladder cancer (MIBC) and low- from high-grade bladder urothelial carcinoma using a fractional-order calculus (FROC) model as well as a combination of FROC DWI and bi-parametric Vesical Imaging-Reporting and Data System (VI-RADS).
METHODS: Fifty-eight participants with bladder urothelial carcinoma were included in this IRB-approved prospective study. Diffusion-weighted images, acquired with 16 b-values (0-3600 s/mm2), were analyzed using the FROC model. Three FROC parameters, D, β, and μ, were used for delineating NMIBC from MIBC and for tumor grading. A receiver operating characteristic (ROC) analysis was performed based on the individual FROC parameters and their combinations, followed by comparisons with apparent diffusion coefficient (ADC) and bi-parametric VI-RADS based on T2-weighted images and DWI.
RESULTS: D and μ were significantly lower in the MIBC group than in the NMIBC group (p = 0.001 for each), and D, β, and μ all exhibited significantly lower values in the high- than in the low-grade tumors (p ≤ 0.011). The combination of D, β, and μ produced the highest specificity (85%), accuracy (78%), and the area under the ROC curve (AUC, 0.782) for distinguishing NMIBC and MIBC, and the best sensitivity (89%), specificity (86%), accuracy (88%), and AUC (0.892) for tumor grading, all of which outperformed the ADC. The combination of FROC parameters with bi-parametric VI-RADS improved the AUC from 0.859 to 0.931.
CONCLUSIONS: High b-value DWI with a FROC model is useful in distinguishing NMIBC from MIBC and grading bladder tumors.
KEY POINTS: • Diffusion parameters derived from a FROC diffusion model may differentiate NMIBC from MIBC and low- from high-grade bladder urothelial carcinomas. • Under the condition of a moderate sample size, higher AUCs were achieved by the FROC parameters D (0.842) and μ (0.857) than ADC (0.804) for bladder tumor grading with p ≤ 0.046. • The combination of the three diffusion parameters from the FROC model can improve the specificity over ADC (85% versus 67%, p = 0.031) for distinguishing NMIBC and MIBC and enhance the performance of bi-parametric VI-RADS.
引用
- Feng C, Wang Y, Dan G, et al. Evaluation of a fractional-order calculus diffusion model and bi-parametric VI-RADS for staging and grading bladder urothelial carcinoma. Eur Radiol. 2021. PMID: 34342693. doi:10.1007/s00330-021-08203-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。