文献速递腹部MR

1.5T磁共振弹性成像评估疑似弥漫性肝病:GRE与SE-EPI序列自身对照比较及混杂因素分析

MR elastography in patients with suspected diffuse liver disease at 1.5T: Intraindividual comparison of gradient-recalled echo versus spin-echo echo-planar imaging sequences and investigation of potential confounding factors.
PubMed 文献 · Eur J Radiol · 2021-08-05

该研究在305例疑似弥漫性肝病患者中,于1.5T比较GRE-MRE与SE-EPI-MRE及短TE-SE-EPI-MRE测量的肝硬度值,并分析脂肪、铁、年龄和性别的影响。结果显示三种序列肝硬度一致性良好,但GRE-MRE因铁过载导致不可用结果显著增多。

要点

  • GRE-MRE与SE-EPI-MRE肝硬度一致性良好(CCC 0.94),但GRE-MRE在铁过载患者中失败率显著更高。
  • SE-EPI-MRE和hiSE-EPI-MRE成功率高,仅约3%不可用,且不可用者铁负荷更高。
  • 脂肪、年龄和性别对三种序列的成功率无显著影响。

核心结论

  • GRE-MRE与SE-EPI-MRE测量的肝硬度值一致性良好。
  • GRE-MRE检查成功率显著低于SE-EPI-MRE,主要受肝铁含量影响。

研究设计与样本

  • 单中心自身对照研究,纳入305例疑似弥漫性肝病患者(男225例,女80例,平均年龄51.12岁)。
  • 在1.5T设备上分别采用GRE-MRE、SE-EPI-MRE和短TE-SE-EPI-MRE(hiSE-EPI-MRE)序列测量肝硬度。
  • 采用Bland-Altman图和一致性相关系数(CCC)比较序列间肝硬度值,并评估成功率与混杂因素的关系。

关键影像表现/征象

  • GRE-MRE与SE-EPI-MRE肝硬度平均差异(偏倚)为0.15 kPa(一致性限-0.72至0.41 kPa)。
  • GRE-MRE与hiSE-EPI-MRE平均差异为0.2 kPa(一致性限-0.94至0.55 kPa)。
  • SE-EPI-MRE与hiSE-EPI-MRE平均差异为0.04 kPa(一致性限-0.62至0.53 kPa)。
  • GRE-MRE不可用结果者72/305例,均有高铁水平(平均R2*=209.7 1/s)。
  • SE-EPI-MRE和hiSE-EPI-MRE不可用结果分别为10/305和8/305例,对应铁负荷更高(平均R2*分别为549.2 1/s和570.7 1/s)。

诊断标准与关键数值

  • GRE-MRE与SE-EPI-MRE肝硬度一致性CCC为0.94(95%CI 0.92-0.95)。
  • GRE-MRE与hiSE-EPI-MRE一致性CCC为0.89(95%CI 0.86-0.91)。
  • SE-EPI-MRE与hiSE-EPI-MRE一致性CCC为0.94(95%CI 0.92-0.95)。

临床应用与阅片要点

  • 在疑似弥漫性肝病患者中,SE-EPI-MRE可作为GRE-MRE的替代序列,尤其适用于铁过载患者。
  • 阅片时应关注肝铁沉积对GRE-MRE成功率的显著影响,必要时改用SE-EPI-MRE。

局限性

  • 原文未明确报告研究局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare liver stiffness (LS) in patients with suspected diffuse liver disease between gradient-recalled-echo magnetic resonance elastography (GRE-MRE) and different spin-echo echo-planar imaging (SE-EPI-MRE) sequences and to investigate confounding factors including fat, iron, age, and sex.

METHOD: LS was measured at 1.5T using GRE-MRE, SE-EPI-MRE and short-TE-SE-EPI-MRE (hiSE-EPI-MRE) sequences and compared using Bland-Altman-plots together with concordance correlation coefficients (CCC). Success gradings were evaluated considering possible confounding factors.

RESULTS: 305 patients (225 male, 80 females, mean age 51.12 years) were included. 109/305 showed hepatic iron overload, 183 hepatic steatosis. The mean difference (bias) in stiffness values between GRE-MRE and SE-EPI-MRE/hiSE-EPI-MRE was 0.15/0.2 kPa (LOA: -0.72,0.41 kPa/-0.94,0.55 kPa), between SE-EPI-MRE and hiSE-EPI-MRE 0.04 kPa (LOA: -0.62,0.53 kPa). The CCC for agreement between stiffness values for GRE-MRE and SE-EPI-MRE was 0.94 (0.92-0.95), 0.89 (0.86-0.91) for hiSE-EPI-MRE and GRE-MRE and 0.94 (0.92-0.95) for SE-EPI-MRE and hiSE-EPI-MRE. Using GRE-MRE, 72/305 showed unusable results whereby all these patients had high iron levels (mean R2*=209.7 1/s). For SE-EPI-MRE and hiSE-EPI-MRE only 10/305 and 8/305 were inconclusive respectively, corresponding to a significantly higher iron load (mean R2*= 549.2 1/s for SE-EPI-MRE and 570.7 1/s for hiSE-EPI-MRE). Concerning fat, age or sex no significant influence on success was observed for all sequences.

CONCLUSIONS: Good agreement of LS values was observed between GRE-MRE and SE-EPI-MRE sequences. The number of successful exams, however, was considerably lower for GRE-MRE, mainly due to iron content. Study reference number: AN5093.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Plaikner M, Kremser C, Zoller H, et al. MR elastography in patients with suspected diffuse liver disease at 1.5T: Intraindividual comparison of gradient-recalled echo versus spin-echo echo-planar imaging sequences and investigation of potential confounding factors. Eur J Radiol. 2021. PMID: 34388628. doi:10.1016/j.ejrad.2021.109898

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。