双能CT无创预测乙肝肝硬化食管静脉曲张出血风险
本研究回顾性纳入317例乙肝肝硬化食管静脉曲张患者,基于双能CT特征构建无创预测模型,并与常规CT模型比较。结果显示联合双能CT特征(胃短静脉碘浓度、脾脏碘浓度)的模型AUC在训练集和验证集均高于常规CT模型,提示双能CT对无创预测食管静脉曲张出血风险有附加价值。
要点
- 联合双能CT特征(胃短静脉碘浓度、脾脏碘浓度)可提高预测食管静脉曲张出血风险的AUC。
- 常规CT特征中食管静脉直径、脾静脉直径和腹水是独立预测因素。
- 双能CT模型在验证集中AUC为0.798,高于常规CT模型的0.738。
局限性
- 回顾性研究,可能存在选择偏倚。
- 单中心研究,样本量有限,需外部验证。
- 模型基于乙肝肝硬化人群,对其他病因肝硬化适用性未知。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Oesophageal variceal bleeding (OVB) is a fatal complication of cirrhosis and/or portal hypertension. We aimed to develop a non-invasive prediction model for the risk of OVB using dual-energy computed tomography (CT).
METHODS: 317 oesophageal varices (OV) patients with hepatitis B virus-related cirrhosis were retrospectively assessed from January 2018 to December 2018. All patients underwent dual-energy CT scans within 14 days before endoscopy. 222 of 317 patients (174 OVB-negative patients and 48 OVB-positive patients) were included in the training cohort and 95 patients (74 OVB-negative patients and 21 OVB-positive patients) were included in the validation cohort chronologically. A model with the selected conventional CT features and a model with the conventional CT and dual-energy CT features were developed. The prediction accuracy was evaluated using the receiver operating characteristic (ROC) curve. The accuracy and reproducibility of the models for OVB risk prediction of cirrhosis were validated by the validation cohort. The areas under the curve (AUC) of the two models were compared with Delong test.
RESULTS: Diameter of oesophageal vein (OV(mm)), diameter of splenic vein (SPV(mm)), ascites (AS), iodine concentration in short gastric vein (SGV(HU)), iodine concentration in spleen (SP(HU)) were independent predictors of OVB risk (P < 0.05). Then, we developed a model with the selected conventional CT features [OV(mm), SPV(mm), AS] and a model with the conventional CT and dual-energy CT features [OV(mm), SPV(mm), AS, SGV(HU), SP(HU)]. The AUCs of the model built with the conventional CT and dual-energy CT features were higher than the model built only with the conventional CT features in the training (0.839 vs 0.809) and validation cohorts (0.798 vs 0.738).
CONCLUSION: The non-invasive prediction model developed with the conventional CT and dual-energy CT features may have added value in noninvasively predicting OVB than the model built only with the conventional CT features and may have significant clinical implications on early prevention and treatment of OVB.
ADVANCES IN KNOWLEDGE: Combination of dual-energy CT with conventional CT may have added value for non-invasive prediction of OVB compared to conventional CT.
引用
- Liu H, Sun J, Liu X, et al. Dual-energy computed tomography for non-invasive prediction of the risk of oesophageal variceal bleeding with hepatitis B cirrhosis. Abdom Radiol (NY). 2021. PMID: 34415412. doi:10.1007/s00261-021-03251-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。