文献速递腹部介入US

低强度超声联合微泡不同机械指数增强胰腺癌化疗的临床前研究

Chemotherapy Augmentation Using Low-Intensity Ultrasound Combined with Microbubbles with Different Mechanical Indexes in a Pancreatic Cancer Model.
PubMed 文献 · Ultrasound Med Biol · 2021-08-04

结果显示MI=0.3可显著提高肿瘤血流和局部多柔比星浓度,而较高MI未见显著增强,且各组的苏木精-伊红染色均未见出血或组织损伤。

要点

  • 低机械指数(MI=0.3)超声联合微泡可增强胰腺癌模型肿瘤血流灌注和药物递送。
  • 较高机械指数(0.7、1.1)未显示显著增强药物浓度的效果。
  • 各治疗组苏木精-伊红染色均未见出血或其他组织损伤。

核心结论

  • 低强度超声在MI=0.3联合微泡可增强胰腺癌裸鼠肿瘤血流灌注并提高局部多柔比星浓度。
  • MI=0.7和1.1时治疗侧与对照侧多柔比星浓度无显著差异。
  • 各机械指数组苏木精-伊红染色均未见出血或其他组织损伤。

研究设计与样本

  • 小鼠随机分为三组,超声机械指数分别设为0.3(A组)、0.7(B组)和1.1(C组)。
  • 每组5只静脉注射荧光染料DiR碘化物,一侧肿瘤接受低强度超声联合微泡治疗,对侧接受假超声,行活体荧光成像检测瘤内DiR富集。
  • 治疗后对比增强超声1小时后处死小鼠测定肿瘤组织多柔比星浓度;每组1只于超声治疗后处死行苏木精-伊红染色。

关键影像表现/征象

  • 对比增强超声定量分析和活体荧光成像证实MI=0.3联合微泡可增强肿瘤血流并提高区域荧光染料DiR碘化物浓度。
  • 苏木精-伊红染色显示所有组治疗侧和对照侧肿瘤标本均未见出血或其他组织损伤。

诊断标准与关键数值

  • MI=0.3组治疗侧多柔比星浓度为1.45 ± 0.53 μg/g,对照侧为1.07 ± 0.46 μg/g,差异有统计学意义(t = -5.163,p = 0.001)。
  • MI=0.7组治疗侧与对照侧多柔比星浓度差异无统计学意义(Z = -0.297,p = 0.766)。
  • MI=1.1组治疗侧与对照侧多柔比星浓度差异无统计学意义(Z = -0.357,p = 0.721)。
  • 对比增强超声采用MI=0.08进行定量分析。

临床应用与阅片要点

  • 临床前结果表明低机械指数(MI=0.3)超声联合微泡可能作为增强胰腺癌化疗药物递送的潜在策略。
  • 较高机械指数(0.7、1.1)在本模型中未显示增强药物浓度的效果,提示机械指数选择对治疗效应至关重要。
  • 苏木精-伊红染色未见组织损伤,提示所测试的超声参数在短期观察中未造成明显组织学损害。

局限性

  • 研究为裸鼠胰腺癌模型,结论外推至人体需谨慎。
  • 仅评估了单次超声治疗后的短期效果,未报告长期疗效或安全性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The aim of the study was to explore the optimal mechanical indexes (MIs) for low-intensity ultrasound (LIUS) combined with microbubbles to enhance tumor blood perfusion and improve drug concentration in pancreatic cancer-bearing nude mice. Fifty-four nude mice bearing bilateral pancreatic tumors on the hind legs were randomly divided into three groups (the MI was set at 0.3, 0.7 and 1.1 in groups A, B and C, respectively). Five nude mice in each group were intravenously injected with the fluorescent dye DiR iodide (DiIC18(7),1,1'-dioctadecyl-3,3,3',3'-tetramethylindotricarbocyanine iodide); for each mouse, one tumor was treated with LIUS combined with microbubbles, and the contralateral tumor was exposed to sham ultrasound. In vivo fluorescence imaging was performed to detect the enrichment of intratumoral DiR iodide. Twelve mice in each group were intravenously injected with doxorubicin (DOX) and underwent ultrasound therapy as described above. Tumor blood perfusion changes were quantitatively evaluated with pre- and post-treatment contrast-enhanced ultrasound (CEUS, MI = 0.08). One hour after the post-treatment CEUS, nude mice were sacrificed to determine the DOX concentration in tumor tissue; one mouse in each group was sacrificed after ultrasound treatment for tumor hematoxylin-eosin staining examination. CEUS quantitative analysis and in vivo fluorescence images confirmed that LIUS at MI = 0.3 combined with microbubbles was able to enhance tumor blood flow and increase regional fluorescence dye DiR iodide concentration. The DOX concentration on the therapeutic side was significantly higher than that on the control side after ultrasound-stimulated (MI = 0.3) microbubble cavitation (USMC) treatment (1.45 ± 0.53 μg/g vs. 1.07 ± 0.46 μg/g, t = -5.163, p = 0.001). However, in groups B and C, there were no significant differences in DOX concentration between the therapeutic and control sides (Z = -0.297, -0.357, p = 0.766, 0.721). No hemorrhage or other tissue damage was observed in hematoxylin-eosin-stained tumor specimens of both sides in all groups. LIUS at MI = 0.3 combined with microbubbles was able to enhance tumor blood perfusion and improve local drug concentration in nude mice bearing pancreatic cancer.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Feng S, Qiao W, Tang J, et al. Chemotherapy Augmentation Using Low-Intensity Ultrasound Combined with Microbubbles with Different Mechanical Indexes in a Pancreatic Cancer Model. Ultrasound Med Biol. 2021. PMID: 34362582. doi:10.1016/j.ultrasmedbio.2021.07.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。