不同呼吸技术对正常胰腺IVIM定量参数的影响
前瞻性研究纳入26名健康志愿者,在3.0T MR上采用自由呼吸、肝顶定位和相位定位三种呼吸技术行胰腺轴位IVIM成像,比较不同解剖位置和呼吸技术下IVIM定量参数的差异。结果显示Dslow、Dfast和f值不受呼吸技术和解剖位置影响,Dslow和f重复测量一致性良好,Dfast一致性较差。
要点
- 正常胰腺IVIM参数Dslow、Dfast、f值在不同呼吸技术和头体尾位置间无显著差异。
- Dslow和f值重复测量一致性良好,Dfast一致性较差,阅片时需注意。
- 自由呼吸、肝顶定位和相位定位三种呼吸技术均可用于胰腺IVIM成像。
局限性
- 样本量较小(26名健康志愿者)。
- 单中心研究。
- 仅纳入健康人群,未验证疾病状态。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To prospectively compare the differences in intravoxel incoherent motion (IVIM)-derived quantitative parameters in different anatomic locations of the normal pancreas with different breathing techniques in a healthy population.
METHOD: Twenty-six volunteers successfully underwent pancreas axial IVIM imaging with a 3.0-T MR system using 11 b-values (from 0 to 1000 sec/mm2) with three different breathing techniques: free breath (FB), liver dome scout (LDS), and phase scout (PS). The IVIM-derived quantitative parameters in three anatomic locations (head, body, and tail of the pancreas) were calculated. The intra-, inter-, and short-term consistency of IVIM-derived quantitative parameters were assessed by comparing 95% confidence interval (CI) of limits of agreement (LOA) of difference between measurements and clinical maximum allowed difference using the Bland-Altman method. The Kruskal-Wallis test was used to compare pancreatic IVIM-derived parameters.
RESULTS: In Bland-Altman graph, the maximum values of the 95% CIs of LOAs of Dslow, Dfast, and f were (0.123 ± 0.022) × 10-3 mm2/sec, (22.093 ± 4.997) × 10-3 mm2/sec, and (3.942 ± 0.621)%, and the consistency of Dslow and f was good and that of Dfast was poor overall. The Dslow, Dfast, and f values of normal pancreas were (1.056 ± 0.121) × 10-3 mm2/sec, (55.755 ± 13.011) × 10-3 mm2/sec, and (26.036 ± 2.361)%, respectively, and there aren't any breathing technique (P > 0.05) or location (P > 0.05) dependent differences.
CONCLUSIONS: Our study shows that IVIM-derived quantitative parameters of the pancreas may not be affected by breathing techniques and anatomic locations. The f and Dslow values have good repeated measurement consistency under different breathing techniques.