低单能DECT提高急性肾盂肾炎炎症病灶检出
回顾性研究纳入45例临床疑急性肾盂肾炎患者,行单源双能CT对比增强检查,比较低单能图像与传统图像对炎症病灶的检出。低单能图像检出病灶数更多(6.4±5.3 vs 4.2±3.8,p<0.02),16%的肾脏仅低单能图像可见明确病灶,SNR和CNR分别提高2倍和1.5倍,所有读片医师均偏好低单能图像。
要点
- 低单能图像可提高肾实质炎性病灶检出数目。
- 约16%的肾脏仅低单能图像显示明确病灶。
- 低单能图像SNR和CNR分别提高2倍和1.5倍。
关键影像表现/征象
- 低单能图像上每例患者检出的炎性病灶数多于传统图像(6.4±5.3 vs 4.2±3.8,p<0.02)。
- 单能图像与传统图像检出病灶数呈线性增加关系(y=0.10X+0.36,R2=0.76)。
- 16%的肾脏中,明确可定义的病灶仅在单能图像上检出。
诊断标准与关键数值
- 低单能图像较传统图像SNR和CNR分别提高2倍和1.5倍(p<0.001)。
- 所有读片医师均偏好单能图像检测炎性病灶(162/180次读片,P<0.05),读片者间信度为79%。
局限性
- 回顾性研究设计。
- 单中心、单源双能CT设备。
- 样本量45例。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To determine whether contrast enhanced DECT low monoenergetic can improve diagnostic conspicuity of inflamed kidney foci in acute pyelonephritis compared to conventional images.
MATERIALS AND METHODS: A retrospective study of 45 patients with clinical signs of acute pyelonephritis undergoing contrast-enhanced exams on a single source-DECT was conducted. Representative conventional and monoenergetic images were randomized and presented to four abdominal radiologists to determine their preference for inflamed kidney foci detection, and to determine the number of foci identified. Clinical impact of monoenergetic images was assessed using multivariant analysis. Contrast and signal to noise ratios were compared between the images using paired t-tests.
RESULTS: A greater number of foci were detected on the low energetic images for each patient (6.4 ± 5.3 vs. 4.2 ± 3.8, p < 0.02). Additionally, a consistent linear increase in the number of detected foci on the monoenergetic compared to the conventional images was seen (y = 0.10X + 0.36 R2 = 0.76). Most notably, in 16% of kidneys a clearly definable focus was detected only on monoenergetic images. SNR and CNR were increased by 2 and 1.5 fold for monoenergetic compared to conventional images (p < 0.001). Monoenergetic images were preferred by all readers for detecting inflamed foci (162/180 reads, P < 0.05), with 79% interreader reliability.
CONCLUSION: Low monoenergetic images enable increased detection of inflamed kidney parenchyma, and permit identification of pathologic foci some of which were not seen on the conventional images. Along with the strong preference of radiologists, these images should be considered beneficial for evaluating acute pyelonephritis.
引用
- Marron D, Nahum GS, Gili D, et al. Low monoenergetic DECT detection of pyelonephritis extent. Eur J Radiol. 2021. PMID: 34339954. doi:10.1016/j.ejrad.2021.109837
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。