超声征象预测儿童肠套叠空气灌肠复位后复发风险
该研究对336例成功行空气灌肠复位的肠套叠患儿随访1年,其中65例复发。单因素及Cox多因素分析显示,包块直径和腹部淋巴结肿大是复发的危险因素,包块直径临界值为2.55 cm,超过此值复发可能性更大。
要点
- 包块直径>2.55 cm提示空气灌肠复位后复发风险增高。
- 腹部淋巴结肿大是复发的独立危险因素(HR=2.078)。
- 出院前可依据上述超声征象对高危患儿加强宣教和随访。
关键影像表现/征象
- 复发组与非复发组在包块直径、套筒外淋巴结是否肿大及套筒方面差异有统计学意义(P < .05)。
- 其他超声特征、临床特征及血液参数两组间无差异(P > .05)。
诊断标准与关键数值
- 包块直径预测复发的临界值为2.55 cm,超过此值复发可能性更大。
- 多因素Cox模型显示包块直径HR=1.395(95% CI: 1.045~1.863),腹部淋巴结HR=2.078(95% CI: 1.118~3.865),P < .05。
临床应用与阅片要点
- 对空气灌肠复位成功的患儿,应测量包块直径并观察腹部淋巴结,直径>2.55 cm或淋巴结肿大者提示复发风险高。
- 上述征象有助于急诊医生在出院时识别高危患儿并向家长交代复发可能性。
局限性
- 原文未明确报告研究局限性。
- 研究为单中心设计,样本量有限,结论需外部验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Intussusception is one of the most common abdominal emergencies in early children. Intussusception recurs in 8-20% of children after successful nonoperative reduction. The aim of this study was to explore the ultrasound findings to predict risk of recurrence in pediatric intussusception after air enema reduction.
METHODS: A total of 336 intussusception children were followed up for 1 year after received successful air enema reduction. They were divided into the recurrent group and the non-recurrent group. The differences of clinical characteristics, ultrasonic features, and laboratory tests were analyzed by univariate analyses and the Cox proportional hazard model.
RESULTS: Sixty-five children with recurrent intussusception were identified. There were statistically significances in the diameter of the mass, in the presence or absence of enlarged lymph nodes out of the sleeve, and in the sleeve between recurrent and non-recurrent groups (P < .05). Other ultrasonic features, clinical characteristics, and blood parameters had no differences (P > .05). Multivariate Cox proportional hazard model showed that the diameter of the mass and abdominal lymph nodes may be the risk factors of intussusception recurrence (HR = 1.395, 95% CI: 1.045~1.863 and HR = 2.078, 95% CI: 1.118~3.865, P < .05). The cut-off value of mass diameter was 2.55 cm, above which recurrence is more likely.
CONCLUSIONS: Intussusception recurrence was prone with greater mass diameter (>2.55 cm) and enlarged abdominal lymph nodes. Although these ultrasound findings for recurrence do not necessarily reduce the rate of recurrence, it can predict the recurrent possibility, and help the emergency physicians to be more vigilant in these children and better counsel parents upon discharge.
引用
- Zhang Y, Shao CC, Wei XL, et al. Ultrasound Findings to Predict Risk of Recurrence in Pediatric Intussusception After Air Enema Reduction. J Ultrasound Med. 2021. PMID: 34418137. doi:10.1002/jum.15814
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。