双能CT定量指标与影像组学鉴别胰腺良恶性病变
本研究纳入两个中心共103例接受增强双能CT检查的局灶性胰腺病变患者,比较DECT定量指标与影像组学鉴别良恶性的效能。结果显示两中心AUC分别为0.98-0.99和0.89-0.94,联合两中心数据的监督学习模型AUC最高为0.94(影像组学)和0.90(定量指标),提示DECT定量信息较影像组学更简便且准确。
要点
- DECT定量指标(HU、碘含量、水含量)与影像组学鉴别胰腺良恶性效能相当。
- 两中心数据AUC分别为0.98-0.99和0.89-0.94,联合模型AUC为0.90-0.94。
- 定量DECT信息较复杂影像组学更简便,可作为辅助鉴别工具。
局限性
- 样本量较小(共103例),良恶性比例不均衡。
- 回顾性研究设计。
- 两中心患者年龄差异较大(Site A 68±12岁 vs Site B 46±2岁),可能影响结果泛化性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To compare dual energy CT (DECT) quantitative metrics and radiomics for differentiating benign and malignant pancreatic lesions on contrast enhanced abdomen CT.
MATERIALS AND METHODS: Our study included 103 patients who underwent contrast-enhanced DECT for assessing focal pancreatic lesions at one of the two hospitals (Site A: age 68 ± 12 yrs; malignant = 41, benign = 18; Site B: age 46 ± 2 yrs; malignant = 23, benign = 21). All malignant lesions had histologic confirmation, and benign lesions were stable on follow up CT (>12 months) or had characteristic benign features on MRI. Arterial-phase, low- and high-kV DICOM images were processed with the DECT Tumor Analysis (DETA) to obtain DECT quantitative metrics such as HU, iodine and water content from a region of interest (ROI) over focal pancreatic lesions. Separately, we obtained DECT radiomics from the same ROI. Data were analyzed with multiple logistic regression and receiver operating characteristics to generate area under the curve (AUC) for best predictive variables.
RESULTS: DECT quantitative metrics and radiomics had AUCs of 0.98-0.99 at site A and 0.89-0.94 at site B data for classifying benign and malignant pancreatic lesions. There was no significant difference in the AUCs and accuracies of DECT quantitative metrics and radiomics from lesion rims and volumes among patients at both sites (p > 0.05). Supervised learning-based model with data from the two sites demonstrated best AUCs of 0.94 (DECT radiomics) and 0.90 (DECT quantitative metrics) for characterizing pancreatic lesions as benign or malignant.
CONCLUSION: Compared to complex DECT radiomics, quantitative DECT information provide a simpler but accurate method of differentiating benign and malignant pancreatic lesions.
引用
- Ebrahimian S, Singh R, Netaji A, et al. Characterization of Benign and Malignant Pancreatic Lesions with DECT Quantitative Metrics and Radiomics. Acad Radiol. 2021. PMID: 34412944. doi:10.1016/j.acra.2021.07.008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。