超声联合微泡引导肝脏治疗在活体猪模型中的安全性研究
本研究在8只健康猪中评估超声空化治疗(USCTx)的短期安全性,使用临床级超声设备与造影剂,并在治疗后1周内监测健康指标及急性组织损伤。通过定量分析超声造影、血液和尿液肝损伤生物标志物及组织学,表明该技术及所考虑的参数空间在评估时间范围内是安全的,支持其向临床试验转化以改善化疗药物递送。
要点
- 临床级超声设备联合微泡空化治疗在健康猪模型中未见短期安全性信号。
- 治疗前后超声造影未显示治疗区域灌注改变,血尿肝损伤标志物及组织学未见异常。
- 该研究为首次在大型动物模型中评估相关超声参数下微泡空化的生物效应安全性。
局限性
- 研究仅纳入8只健康猪,样本量小。
- 监测时间仅为1周,缺乏长期安全性数据。
- 研究在健康动物中进行,未在肿瘤或肝病模型中验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Ultrasound and microbubbles are useful for both diagnostic imaging and targeted drug delivery, making them ideal conduits for theranostic interventions. Recent reports have indicated the preclinical success of microbubble cavitation for enhancement of chemotherapy in abdominal tumors; however, there have been limited studies and variable efficacy in clinical implementation of this technique. This is likely because in contrast to the high pressures and long cycle lengths seen in successful preclinical work, current clinical implementation of microbubble cavitation for drug delivery generally involves low acoustic pressures and short cycle lengths to fit within clinical guidelines. To translate the preclinical parameter space to clinical adoption, a relevant safety study in a healthy large animal is required. Therefore, the purpose of this work was to evaluate the safety of ultrasound cavitation treatment (USCTx) in a healthy porcine model using a modified Philips EPIQ with S5-1 as the focused source. We performed USCTx on eight healthy pigs and monitored health over the course of 1 wk. We then performed an acute study of USCTx to evaluate immediate tissue damage. Contrast-enhanced ultrasound exams were performed before and after each treatment to investigate perfusion changes within the treated areas, and blood and urine were evaluated for liver damage biomarkers. We illustrate, through quantitative analysis of contrast-enhanced ultrasound data, blood and urine analyses and histology, that this technique and the parameter space considered are safe within the time frame evaluated. With its safety confirmed using a clinical-grade ultrasound scanner and contrast agent, USCTx could be easily translated into clinical trials for improvement of chemotherapy delivery. This represents the first safety study assessing the bio-effects of microbubble cavitation from relevant ultrasound parameters in a large animal model.
引用
- Keller SB, Wang YN, Totten S, et al. Safety of Image-Guided Treatment of the Liver with Ultrasound and Microbubbles in an in Vivo Porcine Model. Ultrasound Med Biol. 2021. PMID: 34362584. doi:10.1016/j.ultrasmedbio.2021.07.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。