扫描内组织间变异性有助于CT放射组学特征协调化

Intra-scan inter-tissue variability can help harmonize radiomics features in CT.
PubMed 文献 · Eur Radiol · 2021-08-06

该研究利用体模和腹部平扫患者数据,评估CT放射组学特征的可重复性及扫描内组织间变异性。发现56%的测量组合高度可重复,近60%的相对测量相关系数大于0.90。扫描内相对测量可改善组织表征和跨站点协调化。

要点

  • CT放射组学特征的可重复性取决于所测组织或材料。
  • 直方图衍生特征可重复性较低,而GLZLM和GLCM衍生特征相关性最高。
  • 扫描内相对测量可提高检测不同组织间差异的可靠性。

核心结论

  • 部分放射组学特征在组织间呈线性相关,扫描内相对测量可改善组织表征和跨站点协调化。

研究设计与样本

  • 使用17个体模CT扫描和20例腹部平扫患者多站点数据,提取9个放射组学特征进行重复测量分析。

诊断标准与关键数值

  • 56%的测量组合高度可重复;近60%的相对测量相关系数大于0.90。
  • GLZLM和GLCM衍生特征在组织间相关性最高。

临床应用与阅片要点

  • 可利用组织间线性相关特征进行扫描内相对测量,提高检测不同组织差异的可靠性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: We studied the repeatability and the relative intra-scan variability across acquisition protocols in CT using phantom and unenhanced abdominal series.

METHODS: We used 17 CT scans from the Credence Cartridge Radiomics Phantom database and 20 unenhanced multi-site non-pathologic abdominal patient series for which we measured spleen and liver tissues. We performed multiple measurements in extracting 9 radiomics features. We defined a "tandem" as the measurement of a given tissue (or material) by a given radiomics. For each tandem, we assessed the proportion of the variability attributable to repetitions, acquisition protocols, material, or patient. We analyzed the distribution of the intra-scan correlation between pairs of tandems and checked the impact of correlation coefficient greater than 0.90 in comparing paired and unpaired differences.

RESULTS: The repeatability of radiomics features depends on the measured material; 56% of tandems were highly repeatable. Histogram-derived radiomics were generally less repeatable. Nearly 60% of relative radiomics measurements had a correlation coefficient higher than 0.90 allowing paired measurements to improve reliability in detecting the difference between two materials. The analysis of liver and spleen tissues showed that measurement variability was negligible with respect to other variabilities. As for phantom data, we found that gray level zone length matrix (GLZLM)-derived radiomics and gray level co-occurrence matrix (GLCM)-derived radiomics were the most correlating features. For these features, relative intra-scan measurements improved the detection of different materials or tissues.

CONCLUSIONS: We identified radiomics features for which the intra-scan measurements between tissues are linearly correlated. This property represents an opportunity to improve tissue characterization and inter-site harmonization.

KEY POINTS: • The repeatability of radiomics features on CT depends on the measured material or tissue. • Some tandems of radiomics features/tissues are linearly affected by the variability of acquisition protocols on CT. • Relative intra-scan measurements are an opportunity for improving quantitative imaging on CT.