光子计数探测器CT双对比剂双期肝脏成像:一项探索性动物研究
该研究在猪模型中开发单次扫描双对比剂方案,利用光子计数探测器CT同时获取碘增强的晚动脉期和钆增强的门静脉期图像,并结合卷积神经网络去噪。结果显示碘和钆材料图定量误差分别为0.75 mg/mL和0.45 mg/mL,去噪后噪声降低约60%至80%,肝动脉和肝静脉可清晰显示。
要点
- 双对比剂单次扫描可同时获得肝动脉期和门静脉期图像
- CNN去噪显著降低材料图噪声约60%至80%
- 碘和钆材料分解定量准确,RMS误差分别为0.75和0.45 mg/mL
关键影像表现/征象
- 碘和钆材料图可清晰显示含碘的肝动脉和含钆的肝静脉
- 与原始图像相比,CNN去噪后材料图噪声降低约60%至80%
- 去噪后PCD-CT图像衍生的对比材料图中,碘和钆的定量均方根误差分别为0.75 mg/mL和0.45 mg/mL
诊断标准与关键数值
- 碘材料图定量均方根误差为0.75 mg/mL
- 钆材料图定量均方根误差为0.45 mg/mL
- CNN去噪后对比材料图噪声降低约60%至80%
临床应用与阅片要点
- 双对比剂单次扫描有望在一次检查中同时评估肝动脉和门静脉期,减少扫描次数和对比剂用量
- CNN去噪可改善材料分解图像质量,但需注意其可能对定量准确性的影响
- 目前仅为动物实验,临床转化前需进一步验证
局限性
- 探索性动物研究,样本量小(单只猪)
- 单中心研究
- 尚未在人体中验证
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The aims of this study were to develop a single-scan dual-contrast protocol for biphasic liver imaging with 2 intravenous contrast agents (iodine and gadolinium) and to evaluate its effectiveness in an exploratory swine study using a photon-counting detector computed tomography (PCD-CT) system.
MATERIALS AND METHODS: A dual-contrast CT protocol was developed for PCD-CT to simultaneously acquire 2 phases of liver contrast enhancement, with the late arterial phase enhanced by 1 contrast agent (iodine-based) and the portal venous phase enhanced by the other (gadolinium-based). A gadolinium contrast bolus (gadobutrol: 64 mL, 8 mL/s) and an iodine contrast bolus (iohexol: 40 mL, 5 mL/s) were intravenously injected in the femoral vein of a healthy domestic swine, with the second injection initiated after 17 seconds from the beginning of the first injection; PCD-CT image acquisition was performed 12 seconds after the beginning of the iodine contrast injection. A convolutional neural network (CNN)-based denoising technique was applied to PCD-CT images to overcome the inherent noise magnification issue in iodine/gadolinium decomposition task. Iodine and gadolinium material maps were generated using a 3-material decomposition method in image space. A set of contrast samples (mixed iodine and gadolinium) was attached to the swine belly; quantitative accuracy of material decomposition in these inserts between measured and true concentrations was calculated using root mean square error. An abdominal radiologist qualitatively evaluated the delineation of arterial and venous vasculatures in the swine liver using iodine and gadolinium maps obtained using the dual-contrast PCD-CT protocol.
RESULTS: The iodine and gadolinium samples attached to the swine were quantified with root mean square error values of 0.75 mg/mL for iodine and 0.45 mg/mL for gadolinium from the contrast material maps derived from the denoised PCD-CT images. Hepatic arteries containing iodine and veins containing gadolinium in the swine liver could be clearly visualized. Compared with the original images, better distinctions between 2 liver phases were achieved using CNN denoising, with approximately 60% to 80% noise reduction in contrast material maps acquired with the denoised PCD-CT images compared with the original images.
CONCLUSIONS: Simultaneous biphasic liver imaging in a single multienergy PCD-CT acquisition using a dual-contrast (iodine and gadolinium) injection protocol and CNN denoising was demonstrated in a swine study, where the enhanced hepatic arteries (containing iodine) and the enhanced hepatic veins (containing gadolinium) could be clearly visualized and delineated in the swine liver.
引用
- Ren L, Huber N, Rajendran K, et al. Dual-Contrast Biphasic Liver Imaging With Iodine and Gadolinium Using Photon-Counting Detector Computed Tomography: An Exploratory Animal Study. Invest Radiol. 2022. PMID: 34411033. doi:10.1097/RLI.0000000000000815
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。