B-flow/STIC M型超声在灵长类模型检测早孕期螺旋动脉管径下降
本研究在狒狒模型中使用B-flow/STIC M型超声检测早孕期螺旋动脉管径和血流量,发现雌激素处理组(模拟螺旋动脉重塑受损)的收缩期和舒张期管径分别降低31%和50%,血流量降低85%,且与组织学证实的螺旋动脉重塑百分比显著相关。该技术为无创实时评估螺旋动脉重塑提供了新方法。
要点
- B-flow/STIC M型超声可无创检测早孕期子宫螺旋动脉管径和血流量。
- 螺旋动脉重塑受损时,收缩期和舒张期管径分别降低31%和50%。
- 超声测得的螺旋动脉管径与组织学重塑百分比显著相关(P<0.05)。
关键影像表现/征象
- B-flow/STIC M型超声可实时显示子宫螺旋动脉在心动周期中的管径变化。
- 螺旋动脉重塑受抑制的狒狒中,收缩期和舒张期螺旋动脉管径分别降低31%(P=0.014)和50%(P=0.005),血流量降低85%(P=0.014)。
诊断标准与关键数值
- 螺旋动脉管径>50µm且被绒毛外滋养细胞重塑的比例在雌激素处理组比未处理组低70%(P=0.000001)。
- 超声测得的螺旋动脉管径与组织学证实的螺旋动脉重塑百分比显著相关(P<0.05)。
临床应用与阅片要点
- 阅片时可利用B-flow/STIC M型超声观察早孕期子宫螺旋动脉的管径和血流随心动周期的变化。
- 螺旋动脉管径减小和血流量降低可能提示螺旋动脉重塑受损。
局限性
- 本研究为动物模型(狒狒)研究,结果需在人类中验证。
- 样本量较小,且为单中心实验设计。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To determine if B-flow/spatiotemporal image correlation (STIC) M-mode ultrasonography detects a decrease in spiral artery luminal diameter and volume flow during the first trimester in a non-human primate model of impaired spiral artery remodeling (SAR).
METHODS: Pregnant baboons were treated daily with estradiol benzoate on days 25-59 of the first trimester (term, 184 days), or remained untreated. On day 60 of gestation, spiral artery luminal diameter (in seven untreated and 12 estradiol-treated baboons) and volume flow (in four untreated and eight estradiol-treated baboons) were quantified by B-flow/STIC M-mode ultrasonography. In addition, in 15 untreated and 18 estradiol-treated baboons, the percent of spiral arteries remodeled by extravillous trophoblasts was quantified ex vivo by immunohistochemical image analysis on placental basal plate tissue collected via Cesarean section on day 60. Findings were compared between treated and untreated animals. The correlation between spiral artery luminal diameter and percent of SAR was assessed in three untreated and six estradiol-treated baboons which underwent both B-flow/STIC M-mode ultrasound and quantification of SAR.
RESULTS: The proportion of spiral arteries greater than 50 µm in diameter remodeled by extravillous trophoblasts was 70% lower in estradiol-treated baboons than in untreated animals (P = 0.000001). Spiral artery luminal diameter in systole and diastole, as quantified by B-flow/STIC M-mode in the first trimester of pregnancy, was 31% (P = 0.014) and 50% (P = 0.005) lower, respectively, and volume flow was 85% lower (P = 0.014), in SAR-suppressed baboons compared with untreated animals. There was a significant correlation between spiral artery luminal diameter as quantified by B-flow/STIC M-mode ultrasonography and the percent of SAR (P < 0.05).
CONCLUSION: B-flow/STIC M-mode ultrasonography provides a novel real-time non-invasive method to detect a decrease in uterine spiral artery luminal diameter and volume flow during the cardiac cycle, reflecting decreased distensibility of the vessel wall, in the first trimester in a non-human primate model of defective SAR. © 2021 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Turan OM, Babischkin JS, Aberdeen GW, et al. B-flow/spatiotemporal image correlation M-mode: novel ultrasound method that detects decrease in spiral artery luminal diameter in first trimester in primate model of impaired spiral artery remodeling. Ultrasound Obstet Gynecol. 2022. PMID: 34358371. doi:10.1002/uog.23753