文献速递儿科影像心血管技术与安全USMR

三个解剖标志处主动脉直径测量对新生儿左心室输出量计算的影响

Impact of Aortic Diameter Measurements at Three Anatomical Landmarks on Left Ventricular Output Calculation in Neonates.
PubMed 文献 · J Ultrasound Med · 2021-08-23

本研究评估新生儿超声左心室输出量(LVO)定量时,在主动脉瓣铰合处(AV)、主动脉窦(AS)和窦管交界(STJ)测量左室流出道直径(LVOTD)的可重复性和准确性。第一队列48名极早产儿中,AV处测量的观察者间偏差和一致性界限最窄;第二队列10名较大新生儿中,AV处测量的LVO与MRI一致性最强(偏差-10.6 ml/kg/min)。结论:AV处测量主动脉直径时,超声LVO定量的可重复性和准确性更好。

要点

  • 新生儿超声LVO定量时,LVOTD应在主动脉瓣铰合处(AV)测量,可重复性最佳。
  • AV处测量的LVO与MRI一致性优于AS和STJ处测量。
  • AS和STJ处测量LVOTD的观察者间变异较大,可能导致LVO偏差增大。

诊断标准与关键数值

  • 第一队列观察者间LVOTD偏差(95% LOA):AV处0(-0.3至0.3)mm,AS处0(-0.7至0.7)mm,STJ处0(-0.8至0.7)mm。
  • 第一队列观察者间LVO偏差(95% LOA):AV处-1.3(-31至33)ml/kg/min,AS处-0.5(-88至87)ml/kg/min,STJ处-7.2(-83至69)ml/kg/min。
  • 第二队列超声与MRI的LVO偏差(LOA):AV处-10.6(-74至52)ml/kg/min,AS处194(-0.5至388)ml/kg/min,STJ处43(-72至159)ml/kg/min。

临床应用与阅片要点

  • 新生儿超声LVO定量时,建议在主动脉瓣铰合处测量LVOTD以提高重复性和准确性。
  • 避免在主动脉窦或窦管交界处测量LVOTD,因其观察者间变异较大且与MRI一致性较差。

局限性

  • 第一队列仅纳入极早产儿,第二队列样本量小(10名新生儿),结果外推需谨慎。
  • 观察性研究设计,未评估不同操作者经验水平对测量的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess reproducibility and accuracy of left ventricular output (LVO) quantifications in neonates, when left ventricular outflow tract diameter (LVOTD) was measured at the hinges of the aortic valve (AV), at the aortic sinus (AS), and at the sinotubular junction (STJ).

METHODS: This was an observational study. In the first cohort of very preterm neonates, we assessed intraobserver and interobserver repeatability of LVOTD measured at the AV, AS, and STJ and of the corresponding LVO. In the second cohort of older neonates, we compared paired LVO measurements by echo and magnetic resonance imaging (MRI).

RESULTS: In the first cohort of 48 neonates, mean (standard deviation) weight and age at scan were 1046 (302) g and 28.1 (2.7) weeks. Interobserver bias (95% limits of agreement [LOA]) for LVOTD at the AV, AS, and STJ was 0 (-0.3 to 0.3) mm, 0 (-0.7 to 0.7) mm, and 0 (-0.8 to 0.7) mm, respectively. Interobserver bias (95% LOA) for the corresponding LVO was -1.3 (-31 to 33) ml/kg/min, -0.5 (-88 to 87) ml/kg/min, and -7.2 (-83 to 69) ml/kg/min, respectively. In the second cohort of 10 neonates, median (range) weight and age at scan were 1942 (970-3640) g and 37.2 (31.7-39.8) weeks. LVO measured at the AV showed stronger agreement with MRI: bias (LOA) -10.6 (-74 to 52) ml/kg/min, compared to LVO measured at AS and STJ: 194 (-0.5 to 388) ml/kg/min and 43 (-72 to 159) ml/kg/min respectively.

CONCLUSIONS: Reproducibility and accuracy of LVO quantification by echo were better when aortic diameter was measured at AV.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Ficial B, Bonafiglia E, Gangemi A, et al. Impact of Aortic Diameter Measurements at Three Anatomical Landmarks on Left Ventricular Output Calculation in Neonates. J Ultrasound Med. 2021. PMID: 34423855. doi:10.1002/jum.15808

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。