心脏MRI测量的右心室射血分数可预测植入式心律转复除颤器患者的心血管事件
本研究为多中心回顾性观察研究,纳入411例在植入ICD前接受心脏MRI的患者,中位随访63个月。结果显示,心脏MRI测量的右心室射血分数(RVEF)是ICD患者发生适当放电或死亡的独立预测因子,RVEF每降低10%,主要终点风险增加21%。
要点
- RVEF是ICD患者适当放电或死亡的独立预测因子,每降低10%风险增加21%。
- RVEF对全因死亡也有独立预测价值,每降低10%风险增加25%。
- RVEF的预测作用不受ICD适应证、缺血性病因或LVEF影响。
局限性
- 回顾性研究设计
- 未报告其他明显局限
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Right ventricular ejection fraction (RVEF) is an independent predictor of death and adverse cardiovascular outcomes in patients with various cardiac conditions. Purpose To investigate whether RVEF, measured with cardiac MRI, is a predictor of appropriate shock or death in implantable cardioverter-defibrillator (ICD) recipients for primary and secondary prevention of sudden cardiac death. Materials and Methods This retrospective, multicenter, observational study included patients who underwent cardiac MRI before ICD implantation between January 2007 and May 2017. Right ventricular end-diastolic and end-systolic volumes and RVEF were measured with cardiac MRI. The primary end point was a composite of all-cause mortality or appropriate ICD shock. The secondary end point was all-cause mortality. The association between RVEF and primary and secondary outcomes was evaluated by using multivariable Cox regression analysis. Potential interactions were tested between primary prevention, ischemic cause, left ventricular ejection fraction (LVEF), and RVEF. Results Among 411 patients (mean age ± standard deviation, 60 years; 315 men) during a median follow-up of 63 months, 143 (35%) patients experienced an appropriate ICD shock or died. In univariable analysis, lower RVEF was associated with greater risks for appropriate ICD shock or death and for death alone (log-rank trend test, P = .003 and .005 respectively). In multivariable Cox regression analysis adjusting for age at ICD implantation, LVEF, ICD indication (primary vs secondary), ischemic heart disease, and late gadolinium enhancement, RVEF was an independent predictor of the primary outcome (hazard ratio [HR], 1.21 per 10% lower RVEF; 95% CI: 1.04, 1.41; P = .01) and all-cause mortality (HR, 1.25 per 10% lower RVEF; 95% CI: 1.01, 1.55; P = .04). No evidence of significant interactions was found between RVEF and primary or secondary prevention (P = .49), ischemic heart disease (P = .78), and LVEF (P = .29). Conclusion Right ventricular ejection fraction measured with cardiac MRI was a predictor of appropriate implantable cardioverter-defibrillator shock or death. © RSNA, 2021 See also the editorial by Nazarian and Zghaib in this issue. An earlier incorrect version of this article appeared online. This article was corrected on August 24, 2021.
引用
- Jimenez-Juan L, Ben-Dov N, Goncalves Frazao CV, et al. Right Ventricular Function at Cardiac MRI Predicts Cardiovascular Events in Patients with an Implantable Cardioverter-Defibrillator. Radiology. 2021. PMID: 34402663. doi:10.1148/radiol.2021210246
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。