全心脏覆盖CT在房颤TAVI候选者中的图像质量与诊断效能
CT辐射剂量3.25±1.39 mSv,对比剂58.14±12.34 mL,整体主观图像质量评分3.99±0.96,各冠脉平均CT值均>400 HU。以ICA为参考,CT诊断>50%狭窄的敏感度分别为97.06%(血管水平)和100%(患者水平),特异度96.23%和89.06%,阴性预测值99.7%和100%。
要点
- 房颤TAVI候选者行全心脏覆盖CT可获良好冠脉图像质量,各支CT值均>400 HU。
- 该检查排除阻塞性冠心病的敏感度和阴性预测值高,患者水平敏感度100%、NPV 100%。
- 阳性预测值较低(血管73.3%、患者77.4%),阳性发现需结合ICA确认。
核心结论
- 全心脏覆盖TAVI规划CT在房颤TAVI候选者中提供良好CCTA图像质量,排除阻塞性冠心病具有高敏感度和NPV。
研究设计与样本
- 以有创冠脉造影为参考标准,按血管水平和患者水平计算CT诊断效能,并评估图像质量、对比剂用量和有效剂量。
- 采用5分视觉量表评估主观图像质量,测量左主干、左前降支、左回旋支和右冠状动脉的CT值及信噪比。
关键影像表现/征象
- 共分析1371/1408(97.4%)条直径>1.5 mm的节段。
- 整体主观图像质量平均评分3.99±0.96。
- 左主干、右冠状动脉、左回旋支和左前降支的平均CT值均>400 HU。
诊断标准与关键数值
- 以ICA为参考,诊断>50%狭窄的血管水平敏感度97.06%、特异度96.23%、NPV 99.7%、PPV 73.3%。
- 患者水平敏感度100%、特异度89.06%、NPV 100%、PPV 77.4%。
- CCTA有效剂量3.25±1.39 mSv,对比剂用量58.14±12.34 mL。
临床应用与阅片要点
- 房颤TAVI候选者术前规划CT可同时评估冠脉,高NPV有助于排除阻塞性冠心病。
- PPV较低,CT阳性发现(>50%狭窄)需ICA进一步确认。
- 主观图像质量评分和CT值测量可作为日常评估图像是否满足诊断的参考。
局限性
- 回顾性单中心设计。
- 仅纳入房颤TAVI候选者,结果外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the image quality and diagnostic performance for obstructive coronary artery disease of transcatheter aortic valve implantation (TAVI) patients with atrial fibrillation (AF) during TAVI planning CT using a whole-heart coverage CT scanner.
METHODS: Eighty-eight consecutive TAVI candidates with AF (50 men, 74 ± 6 years) who underwent both TAVI planning CT and invasive coronary catheter angiography (ICA) were retrospectively analyzed. With ICA results as the reference standard, the accuracy of TAVI planning CT for lesion detection on a per-vessel and per-patient level was calculated. Meanwhile, image quality, contrast volume, and effective dose (ED) were evaluated. A 5-point visual scale (1-5) was used to assess the subjective image quality. The CT value and signal-to-noise ratio were measured for the left main coronary artery (LM), left anterior descending (LAD), left circumflex (LCX), and right coronary arteries (RCA).
RESULTS: The ED for CCTA was 3.25 ± 1.39 mSv and contrast volume was 58.14 ± 12.34 mL. A total of 1371 (1371/1408 = 97.4%) segments with diameter > 1.5 mm were analyzed. For the subjective evaluation, the mean score was 3.99 ± 0.96 for overall image quality. The mean CT values in LM, RCA, LCX, and LAD were all above 400 HU. For the detection of > 50% stenosis, TAVI planning CT provided on the per-vessel and per-patient basis 97.06% and 100% in sensitivity, 96.23% and 89.06% in specificity, 99.7% and 100% in negative predictive value, and 73.3% and 77.4% in positive predictive value, respectively.
CONCLUSION: TAVI planning CT with whole-heart coverage demonstrates good CCTA image quality and a high sensitivity and NPV in excluding obstructive CAD in TAVI candidates with AF.
KEY POINTS: • Transcatheter aortic valve implantation planning (TAVI) CT with whole-heart coverage enables good image quality of CCTA in TAVI candidates with atrial fibrillation. • Obstructive coronary artery disease may be excluded with high accuracy in transcatheter aortic valve implantation (TAVI) candidates with atrial fibrillation with the usage of whole-heart coverage TAVI planning CT.
引用
- Zhang Y, Li Z, You Y, et al. Image quality and diagnostic performance evaluation in transcatheter aortic valve implantation candidates with atrial fibrillation using a whole-heart coverage CT scanner. Eur Radiol. 2021. PMID: 34338842. doi:10.1007/s00330-021-08187-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。