文献速递胸部CT

深度学习计算机辅助检测系统在大型教学医院检测肺结节的临床评估

Clinical evaluation of a deep-learning-based computer-aided detection system for the detection of pulmonary nodules in a large teaching hospital.
PubMed 文献 · Clin Radiol · 2021-08-14

本研究回顾性分析145例胸部CT,比较深度学习CAD软件与三位放射科医生共识参考标准。CAD敏感度88%,平均每扫描1.04个假阳性,阴性预测值95%。CAD结节成分与参考标准一致率95%,但23个结节存在大小差异,其中19个CAD测量偏大。结论认为系统性能良好但尚不能替代放射科医生。

要点

  • CAD敏感度88%,每扫描假阳性1.04个,阴性预测值95%。
  • CAD对结节大小存在高估倾向,可能导致过多随访检查。
  • CAD结节成分判断与参考标准一致率95%。

核心结论

  • DL-CAD系统敏感度88%、假阳性率1.04个/扫描,与厂商规格相符,结合95%阴性预测值性能良好,但仍不足以替代放射科医生进行结节检测。
  • 观察到CAD对结节大小高估率较高,可能导致过多随访检查。

研究设计与样本

  • 回顾性分析145例胸部CT检查,比较DL-CAD软件输出与三位放射科医生共识阅读的参考标准。
  • 记录每个结节的位置、成分和轴位最大直径;使用97例无结节胸部CT亚组确定给定临床敏感度阈值下的阴性预测值。

关键影像表现/征象

  • 放射科医生发现91个结节,CAD系统发现130个结节,其中80个为真阳性。
  • 23个结节存在大小差异,其中19个(83%)被放射科医生测量得更小。
  • CAD结果与参考标准在结节成分上的一致率为95%。

诊断标准与关键数值

  • 敏感度88%,平均假阳性率1.04个假阳性/扫描,阴性预测值95%。
  • 敏感度、假阳性率和阴性预测值基于三位放射科医生共识参考标准及给定临床敏感度阈值设置。

临床应用与阅片要点

  • CAD可作为结节检测的辅助工具,但需注意其假阳性及结节大小高估可能增加不必要的随访。
  • 阅片时应结合CAD提示与自身判断,特别关注CAD测量偏大的结节,避免过度随访。

局限性

  • 回顾性单中心研究,样本量145例,参考标准基于三位放射科医生共识。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate a deep-learning-based computer-aided detection (DL-CAD) software system for pulmonary nodule detection on computed tomography (CT) images and assess its added value in the clinical practice of a large teaching hospital.

MATERIALS AND METHODS: A retrospective analysis was performed of 145 chest CT examinations by comparing the output of the DL-CAD software with a reference standard based on the consensus reading of three radiologists. For every nodule in each scan, the location, composition, and maximum diameter in the axial plane were recorded. The subgroup of chest CT examinations (n = 97) without any nodules was used to determine the negative predictive value at the given clinical sensitivity threshold setting.

RESULTS: The radiologists found 91 nodules and the CAD system 130 nodules of which 80 were true positive. The measured sensitivity was 88% and the mean false-positive rate was 1.04 false positives/scan. The negative predictive value was 95%. For 23 nodules, there was a size discrepancy of which 19 (83%) were measured smaller by the radiologist. The agreement of nodule composition between the CAD results and the reference standard was 95%.

CONCLUSIONS: The present study found a sensitivity of 88% and a false-positive rate of 1.04 false positives/scan, which match the vendor specification. Together with the measured negative predictive value of 95% the system performs very well; however, these rates are still not good enough to replace the radiologist, even for the specific task of nodule detection. Furthermore, a surprisingly high rate of overestimation of nodule size was observed, which can lead to too many follow-up examinations.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Martins Jarnalo CO, Linsen PVM, Blazís SP, et al. Clinical evaluation of a deep-learning-based computer-aided detection system for the detection of pulmonary nodules in a large teaching hospital. Clin Radiol. 2021. PMID: 34404517. doi:10.1016/j.crad.2021.07.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。